3.3. Electrical requirements
3.3.1. Previous requirements
CHECK THAT THE POWER AND FREQUENCY OF THE ELECTRICAL SUPPLY CORRESPONDS TO
THOSE OF THE WASHER. Check the nameplate posted on the back panel of the machine.
ALL MATERIAL USED IN THE ELECTRIC INSTALLATION MUST COMPLY WITH THE REGULATIONS
CURRENTLY IN FORCE IN EACH COUNTRY.
ALWAYS CONNECT THE GROUND EXTERNAL PROTECTION CIRCUIT. THIS UNIT MUST BE
CONNECTED TO THE GROUND INSTALLATION WITH A CONDUCTOR CONNECTED TO THE
EQUIPMENT GROUNDING TERMINAL.
Warning specific to machines in USA/CANADA installations.
GROUNDING INSTRUCTION. This machine must be connected to a grounded metal, permanent wiring
system by means of a ground cable connected to the equipment grounding terminal on the machine.
3.3.2. Installation characteristics
Check the specific characteristics on the ELE CTRICAL CONNECTION table (section 1.6).
Conductor:
Specifications referring to the conductor are based upon a multi-strand copper conductor.
The length of the conductor from the safety switch to the washer must not be longer than 30 ft (10 m.)
If using single-wire conductors, these must be encased within a safety conduit.
The conductor must be fixed to the inlet opening of the machine using a secure connection appropriate for
the type of conductor or safety conduit.
The conductor must be secured against any pulling, crushing or rubbing.
Additional specifications for the conductors: they must comply with the statutory regulations of the country
in which it is to be installed.
TILT MODELS
Electrical conductors must be flexible, capable of accommodatingthe washer movements during the
loading and unloading operations and secured at their ends. Refer to section 4.5.
Circuit breaker. Install an earth-leakage protected circuit breaker.
Characteristics:
installed in an easily accessible place
number of poles and intensity: refer to ELECTRICAL CONNECTION table (section 1.6)
type A.
protected against pulse currents, harmonics, the presence of continuous components... (consult