Cod. G522433
© Copyright 2009, Alliance Laundry System LLC – DO NOT COPY OR TRANSMIT Rev. 00/0510
Installation 23
3.4. Steam connection
Installation characteristics
Before connecting the installation to the steam valve, purge the pipe conduits.
Place a mechanically lockable flow valve in the steam inlet in an accessible place.
Check dimensions and connection diameters in the Installation specs (section 1.4).
Assemble the steam filter to the pneumatic valve inlet.
Assemble the steam inlet hose to the filter inlet.
Respect the steam circulation direction indicated by an arrow on each part.
Connect the steam supply of the installation to the washer inlet.
Safeguard the installation against accidental contact. It is advisable to insulate the installation to prevent heat
loss.
Open the manual valve and check for leaks in the installation.
Models TILT, refer to section 3.4.1
SEAL ALL THREADED UNIONS WITH A PRODUCT WHICH IS APPROPRIATE FOR STEAM PIPE
CONDUITS.
ATTENTION!
The admission of steam in the bath causes strong
vibrations that can damage the inner drum bottom.
To avoid them, the machine has a pneumatic injector
device (fig. 16). To ensure its correct operation, it is
VERY IMPORTANT to perform the following operations:
Check that the steam inlet pressure does not exceed
4bar (60 PSI)
Check that the compressed air feeding pressure is
between 6 and 7bar (87-100 PSI)
Adjust the compressed air injection regulator (fig. 16),
during the steam intake, until noise and vibration are
reduced to a minimum.
Tighten A locknut to fasten the regulator position.
fig. 16