Installation
Machine FoundationA proper foundation is absolutely necessary for UW 2 speed
Do not mount on wooden floors, above ground level, or over basements. Installation must be “slab on grade” or equal.
Thoroughness of detail must be stressed with all foundation work to ensure a stable unit installation, eliminating possibilities of excessive vibration during extract.
CAUTION
Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked.
SW020
The
A concrete base designed to elevate the washer- extractor to a comfortable and more accessible height for loading and unloading laundry may be used. Care must be exercised in the design of such a base due to the force exerted by the machine during extract. This base must be adequately tied in to the existing floor with rebar.
Static and dynamic loads on the floor or foundation are shown in Table 3. This table can be used as a reference when designing floors and foundations.
UW 2 Speed Pocket Hardmount
Floor Load Data
| 35 | 60 |
|
|
|
Static floor load, lbs (kN) | 1174 (5.2) | 1678 (7.5) |
|
|
|
Static pressure, | 184 (8.8) | 188 (9.0) |
lbs/ft2 (kN/m2) |
|
|
Dynamic floor load, | 663 (3.0) | 1179 (5.2) |
lbs (kN) |
|
|
Dynamic pressure, | 104 (5.0) | 132 (6.3) |
lbs/ft2 (kN/m2) |
|
|
Dynamic load frequency, Hz | 8.4 | 7.75 |
|
|
|
Maximum vertical load, | 1448 (6.4) | 2375 (10.6) |
lbs (kN)* |
|
|
Minimum vertical load, | 122 (0.5) | 17 (0.08) |
lbs (kN)* |
|
|
Base moment, lb/ft (kN/m) | 1712 (2.3) | 3709 (5.0) |
|
|
|
*Acting in the downward direction against the floor.
Table 3
18 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232085 |