Connecting External Liquid Supplies to the Washer-Extractor

1.Remove plugs from base. Refer to Figure 15. Plugs are assembled inside the tubing ring.

2.Install strain reliefs, included in the seal nut.

3.Insert tubes through base. Do not remove cups. Tube should extend into the plastic cup, with the exception of the softener tube, which should be routed to the outside of the cup.

4.Tighten the seal nut to prevent tubing from escaping the assembly.

The UW 2 speed washer-extractor has a polypropylene supply dispenser with five supply compartments. Refer to Figure 17.

Do not attempt to make chemical injection electrical connections to points other than those provided specifically for that purpose by the factory.

 

Installation

 

Chemical Injection Supply System

 

 

Number of dry supply compartments

5

 

 

Number of liquid supply connections

5

 

 

Liquid supply connection size,

5/8 (15.9)

in. (mm)

 

 

 

F232085

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

33