
IMPORTANT: Electrical ratings are subject to change. Refer to serial decal for electrical ratings information specific to your machine.
WARNING
This machine must be installed, adjusted, and serviced by qualified electrical maintenance personnel familiar with the construction and operation of this type of machinery. They must also be familiar with the potential hazards involved. Failure to observe this warning may result in personal injury and/or equipment damage, and may void the warranty.
SW004
WARNING
Dangerous voltages are present in the electrical control box(es) and at the motor terminals. Only qualified personnel familiar with electrical test procedures, test equipment, and safety precautions should attempt adjustments and troubleshooting. Disconnect power from the machine before removing the control box cover, and before attempting any service procedures.
SW005
WARNING
Ensure that a ground wire from a proven earth ground is connected to the ground lug near the input power block on this machine. Without proper grounding, personal injury from electric shock could occur and machine malfunctions may be evident.
SW008
Installation
Electrical connections are made at the rear of the control module. The machine must be connected to the proper electrical supply shown on the identification plate attached to the side of the control module.
IMPORTANT: Alliance Laundry Systems warranty does not cover compounds that fail as a result of improper input voltage.
NOTE: Do NOT use fuses in place of a circuit breaker.The
The connection should be shielded in a
Use wire sizes indicated in the Electrical Specifications chart for runs up to 50 feet (15.24 m). Use next larger size for runs of 50 to 100 feet (15.24 to
30.48m). Use 2 sizes larger for runs greater than 100 feet (30.48 m).
For personal safety and for proper operation, the
F232085 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 27 |