Installation
On U4 and earlier model units, a stainless steel box at the right rear of the control module houses a terminal strip which furnishes supply output signals for the chemical injection supply pumps. Refer to Figure 19 for an example of a typical terminal strip decal.
On U5 and later model units, the terminal strip that furnishes the supply output signal for the chemicals injection and supply is located inside the control module at the rear. Access is through the rear panel of the module.
Terminals Supply 1 through Supply 5 provide
120 VAC or 240 VAC fused at 500 mA. (Refer to the decal at the external supply terminal strip to determine whether the
CAUTION
Attempting to obtain 110VAC by using L1 or L2 with the common may damage laundry machine circuitry and/or the chemical injection system. Using a 240VAC power wire in the washer- extractor and an earth ground to obtain 110VAC could cause microprocessor problems.
SW028
Consult the chemical injection supply system instructions for operational details.
MAXF10A | F3A | LINE 1 |
|
|
|
| |
TONEUTRAL |
| LINE 2 |
|
NEUTRAL |
| ||
|
| ||
SPLY | SUPPLY 1 | P/N | |
|
| ||
SPLYTHRU1 | SUPPLY 2 | ||
|
| ||
5 | SUPPLY 3 |
| |
YIELDS | SUPPLY 4 |
| |
120VAC | SUPPLY 5 |
| |
|
|
P043I
Figure 19
Control Function TestThe
1.Check the power supply for such characteristics as correct voltage, phase, and cycles to be certain they are correct for the
2.Open manual
NOTE: If the
3. Apply power to the