Allied Air Enterprises 4HP16LT manual Ball Type Service Valve Valve Open

Models: 4HP16LT

1 30
Download 30 pages 11.16 Kb
Page 10
Image 10
Service Valve

Service Valve

Valve Closed

Stem Cap

Service Port

 

 

Insert hex

To outdoor coil

wrench here

Service

 

Port Cap

 

 

To indoor coil

Schrader valve open

(valve front seated)

to line set when valve is

 

closed (front seated)

 

Insert hex

Stem Cap

wrench here

 

Service Port

 

To outdoor coil

 

Service Port Cap

To indoor coil

 

Schrader

Valve Open

Valve

Figure 10

To Open Liquid or Suction Line Service Valve:

1.Remove stem cap with an adjustable wrench.

2.Use a service wrench with a hex-head extension to back the stem out counterclockwise as far as it will go. Use a 3/16" hex head extension for liquid line service valves and a 5/16" extension for suction line service valves.

3.Replace the stem cap. Tighten finger tight, then tighten an additional 1/6 turn.

To Close Liquid or Suction Line Service Valve:

1.Remove the stem cap with an adjustable wrench.

2.Use a service wrench with a hex-head extension to turn the stem clockwise to seat the valve. Tighten firmly.

3.Replace the stem cap. Tighten finger tight, then tighten an additional 1/6 turn.

Suction Line (Ball Type) Service Valve

Suction line (ball type) service valves function the same way as the other valves; the difference is in the construc- tion (see Figure 11).

Ball Type Service Valve

(Valve Open)

Use adjustable wrench. To open, rotate stem counterclockwise 1/4 turn (90°). To close, rotate stem clockwise 1/4 turn (90°).

Figure 11

The ball valve is equipped with a service port with a factory-installed Schrader valve. A service port cap protects the Schrader valve from contamination and serves as the primary seal.

Leak Testing

After the line set has been connected to the indoor and outdoor units, the line set connections and indoor unit must be checked for leaks.

Ball Type Service ValveManual background WARNING

Fire, Explosion, and Personal Safety Hazard.

Failure to follow this warning could result in damage, personal injury, or death.

Never use oxygen to pressurize or purge refrigeration lines. Oxygen, when exposed to a spark or open flame, can cause damage by fire and/or an explosion, that could result in personal injury or death.

Using an Electronic Leak Detector

1.Connect the high pressure hose of the manifold gauge set to the suction valve service port. (Normally the high pressure hose is connected to the liquid line port; however, connecting it to the suction ports helps

Page 10