Patch 86241-06 For Rapier Switches

17

PCR: 02335

Module: CLASSIFIER

Network affecting: No

The SHOW CLASSIFIER command was not displaying Layer 3 information if the classifier had been created with the parameters ETHFORMAT=SNAP and PROTOCOL={IP0000000800}. This issue has been resolved.

PCR: 02343

Module: PPP

Network affecting: No

When acting as a PPPoE Access Concentrator (AC), if a PPPoE client sent discovery packets without the "host-unique" tag, the discovery packets sent by the AC were corrupted. This issue has been resolved.

PCR: 02346

Module: BGP, IPG

Network affecting: No

It is now possible to set a preference value for dynamically learned routes based on their protocol using the command:

SET IP ROUTE PREFERENCE={DEFAULT1..65535}

PROTOCOL={BGP-EXTBGP-INTOSPF-EXT1OSPF-EXT2OSPF-INTER

OSPF-INTRAOSPF-OTHERRIP}

PCR: 02347

Module: SWI

Network affecting: No

The CREATE CONFIGURATION command was not correctly generating the DISABLE SWITCH HWFILTER and DISABLE SWITCH L3FILTER commands. This issue has been resolved.

PCR: 02348 Module: ENCO

Network affecting: No

When the PAC card was under severe load, the related driver occasionally did not fully transfer all result data from the chip. This caused an actCmdFail error. This issue has been resolved.

PCR: 02354

Module: SCC, SYN, PPP

Network affecting: No

In a previous patch, a fatal error occurred after a RESTART ROUTER command was executed when using PPP over SYN. Also, on AR745 models, PPP was using an 8 MB boundary instead of a 16 MB boundary. These issues have been resolved.

PCR: 02357

Module: FR

Network affecting: No

The following issues have been resolved:

PIM was not sending Hello messages over a Frame Relay (FR) interface.

A fatal error occurred if 64 was entered as the interface value in the DESTROY FRAMERELAY command. The command now only accepts 0-63 for this parameter.

The ADD FRAMERELAY DLC command incorrectly accepted a TYPE parameter. Also, this command was not accepting the ENCAPSULATION parameter.

The CREATE CONFIGURATION command incorrectly generated the CIR and CIRLIMITED parameters for the ADD FRAMERELAY DLC command.

FR interfaces with static DLCs were always shown as DOWN. The status of the interface was not being updated when a circuit was added to the interface.

Patch 86241-05 for Software Release 2.4.1 C613-10340-00 REV E

Page 17
Image 17
Allied Telesis 86241-06 manual PCR Module PPP Network affecting No, PCR Module BGP, IPG Network affecting No