Allied Telesis AT-X510-28GTX, AT-X510-52GTX, AT-X510-52GPX LEDs for the SFP Slots, SFP Slot LEDs

Models: AT-X510-28GPX AT-X510-28GSX AT-X510-52GPX AT-X510-28GTX AT-X510-52GTX

1 90
Download 90 pages 11.79 Kb
Page 36
Image 36
LEDs for the SFP Slots

Chapter 1: Overview

LEDs for the SFP Slots

Table 7. LEDs on the 10/100/1000Base-T Ports on the AT-x510-28GPX

and AT-x510-52GPX Switches (Continued)

LED

State

Description

 

 

 

PoE

Green

The switch is detecting a powered device

 

 

(PD) on the port and is delivering power to

 

 

it.

 

 

 

 

Solid Amber

The switch has shutdown PoE+ on the port

 

 

because of a fault condition.

 

 

 

 

Flashing

The switch is detecting a PD on the port but

 

Amber

is not delivering power to it because the

 

 

maximum power budget has been reached.

 

 

 

 

Off

This LED state can result from the following

 

 

conditions:

 

 

The port is not connected to a PD.

 

 

The PD is powered off.

 

 

The port is disabled in the

 

 

management software.

 

 

PoE is disabled on the port.

 

 

The LEDs on the Ethernet line cards

 

 

are turned off. To turn on the LEDs,

 

 

use the eco-friendly button.

 

 

 

The LEDs for the SFP slots on the AT-x510-28GSX Switch are located between the slots, as shown in Figure 9. Each SFP slot has one LED. The left-hand LED is for the top slot and the right-hand LED is for the bottom slot.

SFP Slot LEDs

Figure 8. SFP Slot LEDs on the AT-x510-28GSX Switch

36

Page 36
Image 36
Allied Telesis AT-X510-28GTX, AT-X510-52GTX, AT-X510-52GPX, AT-X510-28GSX manual LEDs for the SFP Slots, SFP Slot LEDs