Allied Telesis X610-48TS/X, X610-48TS-POE+, X610-24TS-POE+, X610-24SPS/X manual AC Power Connector

Models: X610-48TS/X-POE+ X610-48TS X610-24TS/X X610-24TS/X-POE+ X610-24SPS/X X610-24TS X610-24TS-POE+ X610-48TS/X X610-48TS-POE+

1 128
Download 128 pages 35 Kb
Page 55
Image 55
AC Power Connector

x610 Series Layer 3 Gigabit Ethernet Switches Installation Guide

AC Power Connector

The x610 switches have a single AC power supply socket on the rear panel, which has autoswitch AC inputs. To power the switch on or off, connect or disconnect the power cord.

For countries that require 100-125 VAC installations, the power cord plug provided with the AT-PWR1200 power supply has a 20 Amp, 125 V NEMA 5-20P plug. This plug is only compatible with a NEMA 5-20R receptacle.

See Figure 32.

Manual background G

Manual backgroundW

1965

Figure 32. 100-125 VAC 125 V NEMA 5-20 Plug and Receptacle

Refer to “Technical Specifications” on page 121 for the input voltage range.

55

Page 55
Image 55
Allied Telesis X610-48TS/X, X610-48TS-POE+, X610-24TS-POE+, X610-24SPS/X, X610-24TS/X-POE+ manual AC Power Connector