The following table describes the power state fields:
Field Description
Powering The projector is turning on.
On The projector is on.
Cooling The projector is cooling.
Confirm off Confirm off is a non-selectable power state that is returned during
stage one of the two-button Off sequence.
Idle The projector is off but still receiving power (Standby mode).
Source selection controls
These commands switch input sources. The source type determines which commands can be
accepted.
Command Response Available in Standby
mode
get input input=[field] Yes
set input=[field] input=[field] No
The following table describes the source selection commands:
Command Description
get input Returns the projector’s current input.
set input=[field] Sets the input to one of the selectable fields.
The following table describes the command/response definitions for switches between different
embedded applications on the appliance:
Command Response Powered off
set application [target] application=[current] No
get application application=[current] Yes
The following table describes field definitions for switches between different embedded applications
on the appliance:
Field Possible values Description
Current application
application=whiteboard
lwhiteboard
lweb
lpdf
lviewscreens
The appliance is currently
running this application.
Target application
set application=whiteboard
lwhiteboard
lweb
lpdf
lviewscreens
The appliance is set to the
target application.
A P P E N D I X B
Remotely managing your system through an RS-232 serial interface
88