Altinex MT110-100/102 manual Remove ALL Groups, G1-G8EMPTY, 28. RD, Test, Memory is Good

Models: MT110-100/102

1 26
Download 26 pages 22.75 Kb
Page 19
Image 19

MULTITASKER™

Example:

Group 5 consists of the cards located in slots number 2, 4 and 6. Remove all cards from the group by sending the command [RMG5]. The system will return the following feedback:

[G5=0]

REMOVE ALL GROUPS

Remove all the members from every group, effectively deleting all groups.

Command Format: [RMG*Ui]

Ui = Unit ID (i = # from 0-9)

Example:

Group 5 consists of cards 2, 4 and 6. Group 2 consists of cards 1, 2, 3, 4 and 5. Delete all the groups by sending the command [RMG*].

The system will return the following feedback:

G1-G8:EMPTY

28.[RD]

This command reads and then displays the members in each group.

Command Format: [RDGkUi]

Gk = Group ID (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

The cards in slots 2, 4 and 6 are part of group 5. Read the member data for group 5, by sending the command [RDG5]. The system will return feedback as follows:

[G5=C2C4C6]

The feedback shows G5 (group 5) and then the cards that make up group 5. In this case, group 5 includes C2, C4 and C6.

29.[TEST]

This command performs a series of tests on the internal memory of the card.

Upon completion, the system will display following:

Command Format: [TESTCn]

Cn = Card ID (n = # from 1 to 99)

Example:

Test the internal memory of the MT110-102in slot 4 by sending the command [TESTC4]. The card will respond with the feedback similar to the following:

MEMORY IS GOOD

Otherwise, failures would be indicated in the feedback from the card.

30.[VLO] MT110-102 ONLY

This command sets the absolute volume level for a given output.

Command Format: [VLOmAvCnUi]

m = Output (m = # from 1 to 8)

v= Volume Level (v = # from 1 to 32) Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

There is an MT110-102card in slot 8. Set the output volume on Output 2 to 16 by sending the command [VLO2A16C8].

31.[SEL] MT110-102 ONLY

This command is the output select command. It sets the path to adjust the output volume level for the current matrix. It is used in conjunction with the [ + ] and [ - ] commands.

Command Format: [SELmCnUi]

m= Input No. (m = # from 1 to 16) Cn = Engine Card Slot Number

Ui

= Unit ID (i = # from 0 to 9)

[+]

= Increment level by one

[-]

= Decrement level by one

400-0132-005

18

Page 19
Image 19
Altinex MT110-100/102 manual Remove ALL Groups, G1-G8EMPTY, 28. RD, Test, Memory is Good