Alto-Shaam 1200-TH/III S Ervic E, Tr Oubl E Sho Otin G, Disco Nnect Unit From Power Source Before

Models: 1200-TH/III

1 41
Download 41 pages 29.61 Kb
Page 26
Image 26
S ERVIC E

S ERVIC E

TR OUBL E SHO OTIN G

Err or

 

 

 

 

Possi ble Cause

 

 

 

 

 

Code

Descr ipti on/Results

 

 

Service Required

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E- 10

Air Sensor Fault (sho rted )

 

Air sensor is short ed.

 

 

 

 

 

 

 

Inope

ra tive

Ove n

See follow ing page for air sens or test.

 

 

 

Air sensor defe ctiv e?

 

E- 11

Air Sensor Fault (open)

 

 

Air sensor is open or connec tion fai lure.

 

 

 

 

 

Inope

ra tive

Ove n

 

 

 

 

 

Air sensor defe ctiv e?

See follow ing page for air sens or test.

 

E- 20

Product Probe Faul t (sho rted)

 

Pro duct prob e is shorted

 

 

 

 

 

Ov en will

cook

in time

only

page for prob e sensor

tes t.

 

 

Pro be defective ? See fol lowing

 

E- 21

Product Probe Faul t (open)

 

Pro duct Prob e is open or conne ction failu re.

 

 

 

Ov en will

cook

in time

only

tes t.

 

 

Pro be defective ? See fol lowing

page for prob e sensor

 

E- 30

Under temper ature

 

 

Oven door closed? Door gasket need replacement? Preheat skipped?

 

 

Ove n wil l not reach set

temperatu re

Oven overloa ded or has frozen product? Defective air sensor or prob e?

 

Defective soli d state relay? Bad wire connections or open heating cable?

 

 

 

 

 

Is the high limi t switch tripped?

If none of the above, call service.

 

E- 31

Over temp eratu re

 

 

Sho rte d cabl e? Defe ctiv e solid sta te rela y?

Defe ctiv e air sensor ?

 

 

Ov en w il l shu t d o wn

If none of the abo ve, call servic e.

 

 

 

E- 60

Rea l time clock

error

ra tive

Ove n

Cont rol must be replac ed.

 

 

 

 

 

 

Inope

Thi s error also is displaye d if the uni t has been unpl ugged for more tha n 30

 

 

 

 

 

days. If this is the case the unit shou ld be plugged in wit h the circuit

breaker

 

 

 

 

 

on and the uni t displa ying the E-60 on the front panel for more than 30

 

 

 

 

 

minut es. Once this has been accom plishe d the circu it brea ker should

be

 

 

 

 

 

tur ned to off or the uni t unplugge d for about 10 seconds after which

the unit

 

 

 

 

 

shou ld be turne d on again. This may have to be repe ated .

 

E- 70

Con figura tion connect or erro r

Che ck contro l conne ctions for loose wir es.

If non e, contr ol must be rep laced.

 

 

Inope

ra tive

Ove n

If 125 VAC uni t, volta ge is below 90 VAC. Corre ct.

 

 

E- 78

Volta ge low

Inope

ra tive

Ove n

 

 

 

 

If 208-240 VAC volta ge is below 190 VAC. Cor rect.

 

 

E- 79

Volta ge high

Inope

ra tive

Ove n

If 125 VAC uni t, volta ge is over 130 VAC.

Cor rect.

 

 

 

 

If 208-240 VAC, volt age is over 250 VAC .

Correct .

 

 

E- 80

EEPROM - Fun ction data error

Ove n

Cont act Servic e.

 

 

 

 

 

 

 

Inope

ra tive

Cont act Servic e.

 

 

 

 

 

E- 82

EEPROM - Calibration data error

 

 

 

 

 

 

 

Inope

ra tive

Ove n

Cont act Servic e.

 

 

 

 

 

E- 84

EEPROM - Unit ID error

ra tive

Ove n

 

 

 

 

 

 

 

Inope

Cont act Servic e.

 

 

 

 

 

E- 86

EEPROM - Prese t data erro r

Ove n

 

 

 

 

 

 

 

Inope

ra tive

 

 

 

 

 

 

CAUTION

THIS SECTION IS PROVIDED FORTHE ASSISTANCE OF QUALIFIED SERVICETECHNICIANS ONLYAND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL.

TR OUBL E SHO OTIN G D AN GER

DISCO NNECT UNIT FROM

POWER SOURCE BEFORE

CLEANI NG OR SER VICIN G.

TH/III INSTA LLATI ON /OPERAT IO N/SERVICE MANUAL

PG. 25