[D]
[C]
(506mm)
Water Drain (Side Back)
20•20ESG
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
A = UNTREATED WATER B = TREATED WATER C = ELECTRICAL
D = GAS
| C |
A | Steam |
Vents | |
B | (Top) |
D |
|
[D]
2" (50mm)
(1407mm)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
44" (1118mm) |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 2" |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| (49mm) |
| (56mm) |
|
Water Drain
(Bottom)
(778mm)
(833mm)
|
|
|
|
|
|
|
|
|
|
|
| DIMENSIONS: H x W x D |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| EXTERIOR: |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| EXTERIOR WITH RECESSED DOOR: |
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
| INTERIOR: |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |||||||
WATER REQUIREMENTS |
|
|
|
|
|
|
| WATER QUALITY MINIMUM STANDARDS |
| |||||||||
|
|
| ||||||||||||||||
TWO (2) COLD WATER INLETS - DRINKING QUALITY |
| USING A WATER SUPPLY NOT MEETING | ||||||||||||||||
ONE (1) TREATED WATER INLET: |
| 3/4" NPT* | * Can manifold off of |
| WATER QUALITY STANDARDS WILL VOID THIS WARRANTY. | |||||||||||||
ONE (1) UNTREATED WATER INLET: 3/4" NPT* | one 3/4" line. |
| It is the responsibility of the purchaser to ensure that incoming water supply is | |||||||||||||||
LINE PRESSURE: |
|
|
| 30 to 90 psi | 2.8 to 6.2 bar |
|
| compliant with the specifications listed through adequate treatment measures. | ||||||||||
WATER DRAIN: |
| Installation of the CombiGuardTM Water Filtration System is recommended, but | ||||||||||||||||
| this system may not address all water quality issues present. | |||||||||||||||||
to tHe oven as possiBle. Materials Must WitHstand teMperatures up to 200°f (93°c). |
| |||||||||||||||||
|
|
|
|
|
|
|
| |||||||||||
CLEARANCE REQUIREMENTS |
|
|
|
|
|
|
|
| Contaminant | Inlet Water Requirements (untreated water) | ||||||||
LEFT 6" (152mm) RECOMMENDED SERVICE ACCESS: 18" (457mm) |
|
|
| Free Chlorine | Less than 0.1 ppm (mg/L) | |||||||||||||
|
|
|
| Hardness | Less than 3 gpg (52 ppm) | |||||||||||||
| 20" (508mm) FROM HEAT PRODUCING EQUIPMENT |
|
|
|
|
| ||||||||||||
|
|
|
|
|
| Chloride | Less than 30 ppm (mg/L) | |||||||||||
RIGHT | 4" (102mm) | TOP: 20" (508mm) FOR AIR MOVEMENT |
|
|
|
|
| pH | 7.0 to 8.5 |
| ||||||||
|
|
|
|
| Alkalinity | Less than 50 ppm (mg/L) | ||||||||||||
BACK | 4" (102mm) | BOTTOM: |
|
|
|
|
| |||||||||||
|
|
|
|
| Silica | Less than 12 ppm (mg/L) | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| Total Dissolved Solids (tds) | Less than 60 ppm |
| ||||
GAS REQUIREMENTS (TYPE MUST BE SPECIFIED ON ORDER) |
| INSTALLATION REQUIREMENTS |
| |||||||||||||||
CONNECTED ENERGY LOAD: | 190,000 Btu / hr (Natural Gas) | • Oven must be installed level. |
|
|
| |||||||||||||
|
|
|
|
|
|
|
| 170,000 Btu / hr (Propane) | • Hood installation is required. |
|
|
| ||||||
|
|
|
|
|
| 3/4" NPT |
|
| • Water supply | |||||||||
MINIMUM CONNECTED PRESSURE: |
|
| 5.5" W.C. (Natural Gas) |
|
| required by local code. |
|
|
| |||||||||
|
|
|
|
|
|
|
| 9" W.C. (Propane) |
| • Alternate burner orifice is required for installation sites at | ||||||||
MAXIMUM CONNECTED PRESSURE: 14" W.C. |
|
|
| elevations of 2,000 feet (610m) above sea level. |
| |||||||||||||
|
|
|
|
|
|
|
|
|
| |||||||||
ELECTRICAL (DEDICATED CIRCUIT REQUIRED) |
|
|
|
|
|
|
|
|
| CombiSmoker® | ||||||||
MODEL |
| VOLTAGE | PH | HZ | AMPS | kW |
| AWG |
|
| CORD & PLUG |
| Additional kW | |||||
20•20ESG Touch |
| 120 | 1 |
|
| 60 | 9.0 | 1.04 |
| AWG 12 |
| NEMA |
| SK NOT AVAILABLE | ||||
|
|
| 208 – 240 | 1 |
|
| 60 | 5.0 | 1.04 |
| AWG 12 |
|
| no cord or plug |
| + .7 kw | ||
|
|
| 208 – 240 | 3 |
|
| 60 | 5.0/ph | 1.04 |
| AWG 12 |
|
| no cord or plug |
| + .7 kw | ||
|
|
| 380 – 415 | 3 |
|
| 50 | 2.0/ph | 1.44 |
| AWG 12 |
| Bare End, 3 Wire + ground |
| +.7 kw | |||
20•20ESG |
|
| 120 | 1 |
|
| 60 | 12.2 | 1.40 |
| AWG 12 |
| NEMA |
| SK NOT AVAILABLE | |||
|
|
| 208 – 240 | 3 |
|
| 60 | 4.27/ph | 1.54 |
| AWG 12 |
| Bare End, 3 Wire + ground |
| + .7 kw | |||
WEIGHT |
|
|
|
|
|
|
| CAPACITY |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
NET | 900 lb est | (408 kg) |
|
|
|
|
| 20" x 12" x |
| Forty (40) |
| |||||||
SHIP | 1227 lb |
| (557 kg) |
|
|
|
| GN 1/1: |
| 530 x 325 x 65mm |
| Forty (40) |
| |||||
CRATE DIMENSIONS: (L x W x H) |
|
|
|
| GN 2/1: |
| 650 x 530 x 65mm |
| Twenty (20) |
| ||||||||
| 54" x 49" x 85" |
|
|
|
| 18" x 26" x 1" |
|
| Twenty (20) |
| ||||||||
(1374 x 1245 x 2159mm) |
|
|
| ON WIRE SHELVES ONLY |
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
| 480 lb (218 kg) MAXIMUM |
|
|
| |||
|
|
|
|
|
|
|
|
|
| VOLUME MAXIMUM: 300 quarts (380 liters) |
|
*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY
COMBITOUCH® ESG SERIES • GAS INSTALLATION MANUAL •