ERROR cOdES

Error

Error call Out in display

description of Error

Possible cause

code

 

 

 

 

 

 

 

E34

Steam Generator Drain

Water level in steam

— Scale build up inside the steam generator

 

Pump Fault

generator does not drop

drain pump.

 

 

during cleaning program

— Scale build up inside the steam generator affecting

 

 

 

water level probes.

 

 

 

— Generator drain pump is faulty.

 

 

 

— Connection issue at drain pump.

 

 

 

— No output to pump from relay board.

 

 

 

 

E36

Steam Temperature High

Oven cavity temperature is

— Water supply is shut off.

 

 

too high when operating in

— Low water pressure.

 

 

a steam mode or cleaning

— Wiring or connection issue.

 

 

program

— Water injection pipe obstructed.

 

 

 

— Water fl ow control valve plugged or defective.

 

 

 

— Dual solenoid valve Y-1 obstructed or defective.

 

 

 

— No output to solenoid valve form relay board.

 

 

 

 

E51

No Water In Boiler

Water inside steam generator

— Water supply is shut off.

 

 

does not reach low water

— Low water pressure.

 

 

level

— Generator drain cap missing or loose.

 

 

 

— Generator drain pump is not sealing.

 

 

 

— Generator drain pump elbow leaking.

 

 

 

— Faulty or scaled water level probe.

 

 

 

— Faulty or plugged dual solenoid valve assembly.

 

 

 

— Wiring or connection issue.

 

 

 

— No output to dual solenoid from relay board.

 

 

 

 

E53

Fan Motor High

Fan motor too hot

— Exhaust hood is not operating properly.

 

Temperature

 

— Check LED fl ashes on the Motor Control.

 

 

 

See Motor control Error code list. (page 31).

 

 

 

— Connection Issue on Hall Effect sensor.

 

 

 

— Fan wheel is not operating.

 

 

 

— Hall sensor does not detect motor rotation.

 

 

 

 

E54

Fan Motor 2 High

20•20 lower fan motor too hot

— Exhaust hood is not operating properly.

 

Temperature

 

— Check LED fl ashes on the Motor Control.

 

 

 

See Motor control Error code list. (page 31).

 

 

 

— Connection Issue on Hall Effect sensor.

 

 

 

— Fan wheel is not operating.

 

 

 

— Hall sensor does not detect motor rotation.

 

 

 

 

E55

Vent Not Open

Browning valve does not open

— Alignment issue between motor cam and vent

 

 

 

motor safety switch (micro switch).

 

 

 

— Fault vent valve (motor).

 

 

 

— Fault vent valve safety switch (micro switch).

 

 

 

— Wiring or connection problem.

 

 

 

 

 

 

 