MOBILE EQUIPMENT RESTRAINT

INSTALLATION

MOBILE EQUIPMENT RESTRAINT

The gas Combitherm must use a connector that complies with The Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 CSA 6.16 and addenda Z21.69a-1989. A quick disconnect devise must be installed to comply with The Standard for Quick Disconnect Devices for Use with Gas Fuel, ANSI Z21 CSA 6.9.

Adequate means must be provided to limit the movement of this appliance. Limitation of movement must be made without depending on the connector, the quick disconnect device, nor the associated piping designed to limit appliance movement. If it becomes necessary to disconnect the restraint, it must be reconnected immediately following the return of the appliance to its original position.

1.Install a manual gas shut-off valve along with an approved disconnect device.

2. Install an A.G.A. certified, heavy-duty connector that complies with ANSI Z 21.69 or

CAN 1-6.10m88 along with a quick-disconnect device in compliance with ANSI Z21.41 or CAN 1-6.9m70. Connectors must be installed with a cable restraint to prevent excessive tension from being placed on the connector.

RISk OF ELECTRIC SHOCk. WARNING

RISk OF ELECTRIC SHOCk.

Appliance must be secured

to building structure.

CAUTION

THIS SECTION IS PROVIDED FOR THE ASSISTANCE OF QUALIFIED SERVICE TECHNICIANS ONLY AND IS NOT INTENDED FOR USE BY UNTRAINED OR UNAUTHORIZED SERVICE PERSONNEL.

COMBITOUCH® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 15.

Page 17
Image 17
Alto-Shaam 610ESG, 1218ESG, 1010ESG, 1020ESG, 714ESG, 2020ESG Mobile Equipment Restraint, RISk OF ELECTRIC SHOCk, Installation