Alto-Shaam 1020ESG Installation, ERROR cOdES, Error call Out in display, description of Error

Models: 610ESG 2020ESG 714ESG 1020ESG 1010ESG 1218ESG

1 36
Download 36 pages 7.25 Kb
Page 32
Image 32
Error

INSTALLATION

ERROR cOdES

Error

Error call Out in display

description of Error

Possible cause

code

 

 

 

 

 

 

 

E57

No Rinse Water

During rinse no water

— Water supply is shut off.

 

 

fl ow is detected through

— Low water pressure.

 

 

solenoid valve

— Check wiring to all components mentioned below.

 

 

 

— Flow switch is dirty or defective.

 

 

 

— Dual water solenoid valve obstructed or faulty (Y3.)

 

 

 

— Relay board, high voltage, defective.

 

 

 

 

E93

Communication Error,

Communication error

— Check ribbon cable connections mentioned below.

 

FROM Display Board

between display board and

— Ribbon cable defective.

 

 

low voltage relay board

— Relay board, low voltage, connector defective.

 

 

 

— Display board connector defective.

 

 

 

 

E94

Communication Error,

Communication error

— Check ribbon cable connections mentioned below.

 

TO Display Board

between display board and

— Ribbon cable defective.

 

 

low voltage relay board

— Relay board, low voltage, connector defective.

 

 

 

— Display board connector defective.

 

 

 

 

E98

RB is in Cesius and DB is in

Confl ict of unit confi guration

— Relay board and Data board do not match, use

 

Fahrenheit

in the setup menu

setup menu to change format.

 

 

 

 

E99

RB is in Fahrenheit and DB

Confl ict of unit confi guration

— Relay board and Data board do not match, use

 

is in Cesius

in the setup menu

setup menu to change format.

 

 

 

 

E100

DB is not equal to RB

Software update may have

— Check ribbon cable connections.

 

version. Error generated

failed.

— Ribbon cable defective.

 

by DB.

 

— Relay board, low voltage, connector defective.

 

 

— Display board connector defective.

 

 

 

 

 

 

— Software may need to be updated again.

 

 

 

 

E101

DB is not equal to RB

Software update may have

— Check ribbon cable connections.

 

version. Error generated

failed.

— Ribbon cable defective.

 

by RB.

 

— Relay board, low voltage, connector defective.

 

 

— Display board connector defective.

 

 

 

 

 

 

— Software may need to be updated again.

 

 

 

 

E102

Ventless Hood Fault – Filters

Filter safety switches are not

— Check fi lters are installed and properly seated.

 

Not Present

properly activated.

— Check fi lter switches are not damaged, defective or

 

 

 

dislodged.

 

 

 

 

E103

Ventless Hood Fault – No

Pressure safety switch is not

— Check power switch is on.

 

Pressure

properly activated.

— Check vent motor is turning in the proper direction.

 

 

 

— Pressure switch is mis-wired or defective.

 

 

 

 

 

 

 

see motor control error chart on next page

COMBITOUCH® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 30.

Page 32
Image 32