Alto-Shaam AR-7E Se Rvice, Trou Bles Hooti Ng, Gu Id E, To test probe and air sensor, Error, Code

Models: AR-7E

1 37
Download 37 pages 29.17 Kb
Page 23
Image 23
SE RVICE

 

 

 

 

 

 

 

SE RVICE

 

 

 

 

 

 

 

 

 

 

TROU BLES HOOTI NG

GU ID E

 

 

 

 

 

 

 

 

 

 

 

Error

 

 

 

 

 

 

 

 

Code
Descri ptio n

 

 

 

 

Possible Cause

 

 

E-10

Cavit y air sensor

sho rted

 

Cavity air senso r readin g < 5°F. Verify sensor int egrity .

 

 

 

 

 

 

 

 

See sensor test ins truc tions below.

 

 

E-11

Cavit y air sensor

ope n

 

 

Cavity air senso r readin g > 517°F. Verify sensor inte grity .

 

 

 

 

 

 

 

 

See sensor test ins truc tions below.

 

 

E-20

Pro duct prob e is shor ted

 

Produ ct probe reading < 5°F. Verify sensor integ rity.

 

 

 

Oven will cook in time only

 

 

 

 

 

See sensor test ins truc tions below.

 

 

E-21

Product prob e is open

 

 

Produ ct Probe reading > 517°F. Verify sensor integ rity.

 

 

 

Oven will cook in time only

 

 

 

 

 

See sensor test ins truc tions below.

 

 

E-30

Under tem perature

 

 

Unit has not reac hed set-p oint for more tha n 90 min utes.

 

 

E-31

Over temp era tur e

 

 

 

Unit has been highe r than 25°F above the max imum cavit y set-point for

 

 

 

 

 

 

 

 

more than 2 minute s.

 

 

 

 

 

 

 

 

Note: Hol ding Cabinets with this error cod e are more tha n 145°F highe r

 

 

 

 

 

 

 

 

than the maxim um set- point.

 

 

E-50

Temp. mea sur emen t err or

 

Conta ct fac tory.

 

 

 

 

 

 

 

 

 

 

E-51

Temp. mea sur emen t err or

 

Conta ct fac tory.

 

 

 

 

 

 

 

 

 

 

E-60

Rea l time clock

err or

 

 

Data set to factory default. Ensure that date and time are correct if applicable.

 

 

 

 

 

 

 

 

 

 

E-61

Rea l time clock

err or

 

 

Conta ct fac tory.

 

 

E-78

Voltage low

 

 

 

 

Voltage below 90 VAC on a 125 VAC unit, or bel ow 190 VAC on a

 

 

 

 

 

 

 

 

208-240 VAC uni t. Correct vol tage.

 

 

E-79

Voltage high

 

 

 

 

Voltage over 130 VAC on a 125 VAC uni t, or over 250 VAC on a

 

 

 

 

 

 

 

 

208-240 VAC uni t. Correct vol tage.

 

 

E-80

EEPROM Error

 

 

 

 

Ensure that all tempera tures and tim es are proper ly set.

 

 

 

 

 

 

 

 

Conta ct fac tory if proble m persis ts.

 

 

E-81

EEPROM Error

 

 

 

 

Conta ct fac tory.

 

 

 

 

 

 

 

 

 

 

E-82

EEPROM Error

 

 

 

 

Conta ct fac tory.

 

 

E-83

EEPROM Error

 

 

 

 

EEPROM is not comm unic ati ng with the proce ssor . Possi ble bad EEPRO M

 

 

 

 

 

 

 

 

or proc esso r. Chec k that +12V and GND are wired proper ly on the power

 

 

 

 

 

 

 

 

conne ctor. Conta ct fac tory if proble m persis ts.

 

 

E-85

EEPROM Error

 

 

 

 

Conta ct fac tory.

 

 

E-86

EEPROM Error

 

 

 

 

Stored HAC CP memory corr upted . HACC P Addr ess rese t to 1. Possible bad

 

 

 

 

 

 

 

 

EEPROM. Conta ct fac tory if prob lem persi sts.

 

 

E-87

EEPROM Error

 

 

 

 

Stored offs ets cor rupte d. Offs ets rese t to 0. Contr ol may need a

 

 

 

 

 

 

 

 

recalibrat ion. Possib le bad EEPRO M. Cont act factory if prob lem persist s.

 

 

E-88

EEPROM Error

 

 

 

 

All timer set-points are reset to 1 min ute. Timers , if previou sly on, are now

 

 

 

 

 

 

 

 

off. Poss ible bad EEPRO M.

 

 

E-90

But ton stu ck

 

 

 

 

A button has been hel d down for >60 second s. Adjus t control . Error will

 

 

 

 

 

 

 

 

reset when the proble m has bee n resolved .

 

 

E-dS

Datakey error

 

 

 

 

Datakey digit al sig natu re incom pati ble. Cyc le power , and ins tall compa tible

 

 

 

 

 

 

 

 

Datakey if error pers ists.

 

 

E-dT

Datakey error

 

 

 

 

Datakey inc ompat ible with contro l. Insta ll comp atib le Datake y.

 

 

E-dU

Datakey unplugge d

 

 

Inst all Dat ake y and cycl e power to contro l to clear error.

 

 

 

Note: If in doubt, always

cycle

 

the power to the cont rol and cont act factor y if the problem persist s.

 

 

 

 

 

To test probe and air sensor:

Test probe and air sensor by placin g senso r in ice water bath and usin g an ohmmeter set on the ohm scale. The. reading should be 100 ohm s resistance. If it is more tha n 2 ohm s high er or lower, senso r nee ds to be replaced

AR -7E Roti sser ie Oper ation & Care Manual • 21

Page 23
Image 23
Alto-Shaam AR-7E manual Se Rvice, Trou Bles Hooti Ng, Gu Id E, To test probe and air sensor, Error, Code, Descri ptio n