I N S T A L L A T I O N
ELECTRICAL CONNECTION
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE IDENTIFIED
ON APPLIANCE RATING TAG.
DANGER
APPLIANCES WITH NO CORD
PROVIDED BY FACTORY MUST
BE EQUIPPED WITH A CORD OF
SUFFICIENT LENGTH TO PERMIT
THE APPLIANCE TO BE MOVED
FOR CLEANING.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
Hard wired models:
Hard wired models must be equipped with a country certified external allpole disconnection switch with sufficient contact separation.
If a power cord is used for the connection of the product an oil resistant cord like H05RN or H07RN or equivalent must be used.
DANGER
To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electrical codes or, in the absence of local codes, with the current edition of the National Electrical Code ANSI/ NFPA No. 70. In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1 or local codes.
DANGER
IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT, SERVICE, OR MAINTENANCE COULD RESULT IN SEVERE INJURY, DEATH, OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
1.An electrical wiring diagram is located behind the control panel on the left side of the oven. 3 Phase units must be branch circuit protected with proper ampacities, in accordance with the wiring diagram. A dedicated 30 Amp breaker is required.
2.Wire size for the main incoming power to the unit must match the minimum size listed in the specifications. For supply connections, locate the wire size posted on the label located on the electrical control box cover, behind the service panel.
3.When connecting to a
4.Before operating the oven, check all cable connections in the electrical connection area for tightness since connections can loosen during transport.
NOTE: After both water and electrical connections have been completed, operate the oven
in any cooking mode for a period of 15 minutes and recheck the main power connections at the terminal block to make certain they remain tight.
For CE approved units: To prevent an electrical shock hazard between the appliance and other appliances or metal parts in close vicinity, an
with the following symbol.