ERROR CODES
Error | Error Call Out in Display | Description of Error | Possible Cause |
Code |
|
|
|
|
|
|
|
E57 | No Rinse Water | During rinse no water | — Water supply is shut off. |
|
| flow is detected through | — Low water pressure . |
|
| solenoid valve | — Check wiring to all components mentioned below. |
|
|
| — Flow switch is dirty or defective. |
|
|
| — Dual water solenoid valve obstructed or |
|
|
| faulty (Y3.) |
|
|
| — Relay board, high voltage, defective. |
|
|
|
|
E93 | Communication Error, | Communication error | — Check ribbon cable connections mentioned below. |
| FROM Display Board | between display board and | — Ribbon cable defective . |
|
| low voltage relay board | — Relay board, low voltage, connector defective . |
|
|
| — Display board connector defective . |
|
|
|
|
E94 | Communication Error, | Communication error | — Check ribbon cable connections mentioned below. |
| TO Display Board | between display board and | — Ribbon cable defective . |
|
| low voltage relay board | — Relay board, low voltage, connector defective . |
|
|
| — Display board connector defective . |
|
|
|
|
E98 | RB is in Celsius and DB is | Conflict of unit configuration | — Relay board and Data board do not match, use |
| in Fahrenheit | in the setup menu | setup menu to change format. |
|
|
|
|
E99 | RB is in Fahrenheit and DB | Conflict of unit configuration | — Relay board and Data board do not match, use |
| is in Celsius | in the setup menu | setup menu to change format. |
|
|
|
|
E100 | DB is not equal to RB | Software update may | — Check ribbon cable connections. |
| version. Error generated | have failed. | — Ribbon cable defective . |
| by DB. |
| — Relay board, low voltage, connector defective . |
|
| — Display board connector defective . | |
|
|
| |
|
|
| — Software may need to be updated again . |
|
|
|
|
E101 | DB is not equal to RB | Software update may | — Check ribbon cable connections. |
| version. Error generated | have failed. | — Ribbon cable defective . |
| by RB. |
| — Relay board, low voltage, connector defective . |
|
| — Display board connector defective . | |
|
|
| |
|
|
| — Software may need to be updated again . |
|
|
|
|
E102 | Ventless Hood Fault – | Filter safety switches are | — Check filters are installed and properly seated. |
| Filters Not Present | not properly activated . | — Check filter switches are not damaged, defective |
|
|
| or dislodged . |
|
|
|
|
E103 | Ventless Hood Fault – No | Pressure safety switch is | — Check power switch is on. |
| Pressure | not properly activated . | — Check vent motor is turning in the proper |
|
|
| direction . |
|
|
| — Pressure switch is |
|
|
|
|
CT EXPRESS SERIES • INSTALLATION MANUAL •