Alto-Shaam Combination Oven/Steamer manual Error Codes

Models: Combination Oven/Steamer

1 31
Download 31 pages 30.01 Kb
Page 28
Image 28
Manual background

ERROR CODES

Error

Error Call Out in Display

Description of Error

Possible Cause

Code

 

 

 

 

 

 

 

E57

No Rinse Water

During rinse no water

— Water supply is shut off.

 

 

flow is detected through

— Low water pressure .

 

 

solenoid valve

— Check wiring to all components mentioned below.

 

 

 

— Flow switch is dirty or defective.

 

 

 

— Dual water solenoid valve obstructed or

 

 

 

faulty (Y3.)

 

 

 

— Relay board, high voltage, defective.

 

 

 

 

E93

Communication Error,

Communication error

— Check ribbon cable connections mentioned below.

 

FROM Display Board

between display board and

— Ribbon cable defective .

 

 

low voltage relay board

— Relay board, low voltage, connector defective .

 

 

 

— Display board connector defective .

 

 

 

 

E94

Communication Error,

Communication error

— Check ribbon cable connections mentioned below.

 

TO Display Board

between display board and

— Ribbon cable defective .

 

 

low voltage relay board

— Relay board, low voltage, connector defective .

 

 

 

— Display board connector defective .

 

 

 

 

E98

RB is in Celsius and DB is

Conflict of unit configuration

— Relay board and Data board do not match, use

 

in Fahrenheit

in the setup menu

setup menu to change format.

 

 

 

 

E99

RB is in Fahrenheit and DB

Conflict of unit configuration

— Relay board and Data board do not match, use

 

is in Celsius

in the setup menu

setup menu to change format.

 

 

 

 

E100

DB is not equal to RB

Software update may

— Check ribbon cable connections.

 

version. Error generated

have failed.

— Ribbon cable defective .

 

by DB.

 

— Relay board, low voltage, connector defective .

 

 

— Display board connector defective .

 

 

 

 

 

 

— Software may need to be updated again .

 

 

 

 

E101

DB is not equal to RB

Software update may

— Check ribbon cable connections.

 

version. Error generated

have failed.

— Ribbon cable defective .

 

by RB.

 

— Relay board, low voltage, connector defective .

 

 

— Display board connector defective .

 

 

 

 

 

 

— Software may need to be updated again .

 

 

 

 

E102

Ventless Hood Fault –

Filter safety switches are

— Check filters are installed and properly seated.

 

Filters Not Present

not properly activated .

— Check filter switches are not damaged, defective

 

 

 

or dislodged .

 

 

 

 

E103

Ventless Hood Fault – No

Pressure safety switch is

— Check power switch is on.

 

Pressure

not properly activated .

— Check vent motor is turning in the proper

 

 

 

direction .

 

 

 

— Pressure switch is mis-wired or defective.

 

 

 

 

CT EXPRESS SERIES • INSTALLATION MANUAL • MN-29805 • 26..

Page 28
Image 28