ERROR CODES
Error | Error Call Out in Display | Description of Error | Possible Cause |
Code |
|
|
|
|
|
|
|
E13 | Boiler Temperature High | Boiler temperature | — Scale build up inside steam generator . |
|
| overheats | — Scale build up on water level probe . |
|
|
| — B4 Probe connection problem. |
|
|
| — B4 probe faulty. |
|
|
|
|
E15 | Condensor Temperature | Excess condensor | — Untreated water supply line is shut off. |
| High | temperature | — Untreated water supply line is connected to |
|
|
| warm water . |
|
|
| — B3 probe connection problem. |
|
|
| — B3 probe is faulty. |
|
|
| — Single solenoid valve Y2 obstructed or faulty. |
|
|
| — Wiring or connection problem . |
|
|
| — Relay board, high voltage is not operating. |
|
|
|
|
E20 | HACCP Only - B11 Core | Single point core | — Clean Probe Receptacle Pins with sand paper. |
| Temperature Probe Single | temperature probe defect or | — B11 Single Point Core Temperature probe with |
| Point Fault | disconnected . | quick connect, defective . |
|
|
| — B11 Single Point Core Temperature probe wires |
| Error E20 is not shown in display. |
| with quick connect, disconnected. |
|
| — B11 Single Point Core Temperature probe | |
| Instead a probe sign with “?” is |
| |
|
| receptacle, defective . | |
| shown as popup window. In case |
| |
|
| — B11 Single Point Core Temperature probe | |
| the customer cooks in time mode |
| |
|
| receptacle wires disconnected . | |
| during fi rst step and during second |
| |
|
|
| |
| step switches to probe mode but has |
|
|
| no probe in place, the error E20 will |
|
|
| be shown in the error code list and |
|
|
| HACCP list. |
|
|
|
|
|
|
E21 | N6 Cavity Probe Fault | Cavity temperature probe | — N6 Oven Cavity Temperature probe defective. |
|
| defect or disconnected | — N6 Oven Cavity Temperature connection problem. |
|
|
|
|
E22 | B10 Core Temperature | Multipoint core temperature | — B10 Multipoint Core Temperature probe defective. |
| Probe Multipoint Fault | probe defect or | — B10 Multipoint Core Temperature probe |
|
| disconnected | connection problem . |
|
|
|
|
E23 | B4 Boiler Probe Fault | Boiler temperature probe | — B4 Boiler temperature probe defective. |
|
| defect or disconnected | — B4 probe wires connection problem. |
|
|
|
|
E24 | B5 Bypass Probe Fault | Bypass steam temperature | — B5 Bypass steam temperature probe defective. |
|
| probe defect or | — B5 Bypass steam temperature connection |
|
| disconnected | problem . |
|
|
|
|
E25 | B3 Condensor Probe Fault | Condensor water | — B3 Condensor temperature probe defective. |
|
| temperature probe defect or | — B3 Condensor probe connection problem. |
|
| disconnected |
|
|
|
|
|
E26 | N8 Boiler Safety | Steam generator heating | — N8 Boiler temperature probe defective. |
| Temperature Probe Fault | element protection probe | — N8 probe connection problem. |
|
| defect or disconnected |
|
|
|
|
|
E27 | Boiler Element | Excess steam generator | — Scale build up inside steam generator . |
| Temperature High | safety probe | — Scale build up on water level probe . |
|
|
| — Water level probe connection failure . |
|
|
| — N8 boiler temperature probe defective. |
|
|
| — N8 probe connection problem. |
|
|
| — Steam element contactor(s) stuck closed. |
|
|
| — Wiring or connection problem . |
|
|
|
|