Alto-Shaam Combination Oven/Steamer Error Codes, Instead a probe sign with “?” is, HACCP list

Models: Combination Oven/Steamer

1 31
Download 31 pages 30.01 Kb
Page 26
Image 26
Error E20 is not shown in display.

ERROR CODES

Error

Error Call Out in Display

Description of Error

Possible Cause

Code

 

 

 

 

 

 

 

E13

Boiler Temperature High

Boiler temperature

— Scale build up inside steam generator .

 

 

overheats

— Scale build up on water level probe .

 

 

 

— B4 Probe connection problem.

 

 

 

— B4 probe faulty.

 

 

 

 

E15

Condensor Temperature

Excess condensor

— Untreated water supply line is shut off.

 

High

temperature

— Untreated water supply line is connected to

 

 

 

warm water .

 

 

 

— B3 probe connection problem.

 

 

 

— B3 probe is faulty.

 

 

 

— Single solenoid valve Y2 obstructed or faulty.

 

 

 

— Wiring or connection problem .

 

 

 

— Relay board, high voltage is not operating.

 

 

 

 

E20

HACCP Only - B11 Core

Single point core

— Clean Probe Receptacle Pins with sand paper.

 

Temperature Probe Single

temperature probe defect or

— B11 Single Point Core Temperature probe with

 

Point Fault

disconnected .

quick connect, defective .

 

 

 

— B11 Single Point Core Temperature probe wires

 

Error E20 is not shown in display.

 

with quick connect, disconnected.

 

 

— B11 Single Point Core Temperature probe

 

Instead a probe sign with “?” is

 

 

 

receptacle, defective .

 

shown as popup window. In case

 

 

 

— B11 Single Point Core Temperature probe

 

the customer cooks in time mode

 

 

 

receptacle wires disconnected .

 

during fi rst step and during second

 

 

 

 

 

step switches to probe mode but has

 

 

 

no probe in place, the error E20 will

 

 

 

be shown in the error code list and

 

 

 

HACCP list.

 

 

 

 

 

 

E21

N6 Cavity Probe Fault

Cavity temperature probe

— N6 Oven Cavity Temperature probe defective.

 

 

defect or disconnected

— N6 Oven Cavity Temperature connection problem.

 

 

 

 

E22

B10 Core Temperature

Multipoint core temperature

— B10 Multipoint Core Temperature probe defective.

 

Probe Multipoint Fault

probe defect or

— B10 Multipoint Core Temperature probe

 

 

disconnected

connection problem .

 

 

 

 

E23

B4 Boiler Probe Fault

Boiler temperature probe

— B4 Boiler temperature probe defective.

 

 

defect or disconnected

— B4 probe wires connection problem.

 

 

 

 

E24

B5 Bypass Probe Fault

Bypass steam temperature

— B5 Bypass steam temperature probe defective.

 

 

probe defect or

— B5 Bypass steam temperature connection

 

 

disconnected

problem .

 

 

 

 

E25

B3 Condensor Probe Fault

Condensor water

— B3 Condensor temperature probe defective.

 

 

temperature probe defect or

— B3 Condensor probe connection problem.

 

 

disconnected

 

 

 

 

 

E26

N8 Boiler Safety

Steam generator heating

— N8 Boiler temperature probe defective.

 

Temperature Probe Fault

element protection probe

— N8 probe connection problem.

 

 

defect or disconnected

 

 

 

 

 

E27

Boiler Element

Excess steam generator

— Scale build up inside steam generator .

 

Temperature High

safety probe

— Scale build up on water level probe .

 

 

 

— Water level probe connection failure .

 

 

 

— N8 boiler temperature probe defective.

 

 

 

— N8 probe connection problem.

 

 

 

— Steam element contactor(s) stuck closed.

 

 

 

— Wiring or connection problem .

 

 

 

 

continued on next page

CT EXPRESS SERIES • INSTALLATION MANUAL • MN-29805 • 24..

Page 26
Image 26
Alto-Shaam Combination Oven/Steamer manual Error Codes, Instead a probe sign with “?” is, HACCP list