ROOM-VENTED (Recirculating)

INSTALLATION

STEP 3: PREPARE THE VENTING BLOWER

 

 

blower plate

 

blower unit

mounting screw

 

mounting screw

blower plate

 

 

blower unit

blower unit

 

back plate

back plate

 

exhaust

blower unit

 

ports

exhaust ports

 

Figure 15

Figure 16

ROOM-VENTED (Recirculating)

INSTALLATION:

1.Remove one blower unit mounting screw and two blower plate screws. Remove the blower plate from cabinet. See Figure 17.

2.Carefully lift the blower unit out of the microwave oven.

3.Rotate blower unit so that the exhaust ports face the front of the cabinet. See Figure 18.

4.Place blower unit back into microwave oven.

blower unit

blower plate

mounting screw

mounting screw

blower plate

 

back plate

blower unit

Parts "B"

5. Reattach blower plate to microwave oven. Attach with the

one blower unit mounting screw and then the two blowerFigure 17 plate mounting screws.

See Figure 19.

blower unit mounting screw

exhaust ports

Manual background blower plate Manual backgroundmounting screw

blower plate

back plate

blower unit

Parts "B"

Figure 18

Figure 19

15

Page 15
Image 15