American Dryer Corp MDG-120PVV, MD-170PTVW Type Of Gas, 8.7 mb, 26.1 mb, 14.92 - 29.9 mb, 27.4 mb

Models: MD-170PTVW

1 52
Download 52 pages 9.4 Kb
Page 25
Image 25
TYPE OF GAS

2.Technical Gas Data a. Gas Specifications

 

TYPE OF GAS

 

 

 

 

 

 

 

NATURAL

LIQUID PROPANE

 

 

 

 

 

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

 

 

 

 

 

In-Line Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

11.0 inches W.C.

27.4 mb

 

 

 

 

 

Shaded areas are stated in metric equivalents

*Measured at outlet side of gas valve pressure tap when gas valve is on.

b.Gas Connections

Inlet connection --------------

1” N.P.T.

Inlet supply size --------------

1” Diameter Pipe (minimum)

1)Natural Gas

Regulation is controlled by the dryer’s gas valve’s internal regulator. Incoming supply pressure must be consistent between a minimum of 6.0 inches (14.92 mb) and a maximum of 12.0 inches (29.9 mb) water column (W.C.) pressure.

2)Liquid Propane (L.P.) Gas

Dryers made for use with L.P. gas have the gas valve’s internal pressure regulator blocked open so that the gas pressure must be regulated upstream of the dryer. The pressure measured at each gas valve pressure tap must be a consistent 10.5 inches (26.1 mb) water column. There is no regulator or regulation provided in an L.P. dryer. The water column pressure must be regulated at the source (L.P. tank) or an external regulator must be added to each dryer.

 

 

 

 

TYPE OF GAS

 

Liquid

 

 

 

 

 

 

 

 

 

 

Propane

 

 

 

 

Natural

 

 

Liquid Propane

Model

Btu/hr

kcal/hr

 

 

 

Conversion Kit

 

 

 

 

 

 

 

Rating

Rating

Qty.

D.M.S.*

 

Part No.

Qty.

D.M.S.*

Part No.

Part Number

 

 

MDG-120

375,000

94,500

3

#4

 

140832

3

#30

140819

880886

MDG-170

550,000

138,598

4

#2

 

140839

4

#29

140820

880978

 

 

 

 

 

 

 

 

 

 

 

Shaded areas are stated in metric equivalents

* Drill Measurement Size (D.M.S.) equivalents are as follows:

Natural Gas

#4

=

0.2090” (5.3086 mm).

Liquid Propane Gas

#30

=

0.1285” (3.2639 mm).

Natural Gas

#2

=

0.2210” (5.6134 mm).

Liquid Propane Gas

#29

=

0.1360” (3.4544 mm).

113395 - 6

Maytag Co.

23

Page 25
Image 25
American Dryer Corp MDG-120PVV, MD-170PTVW installation manual Type Of Gas, 8.7 mb, 26.1 mb, 14.92 - 29.9 mb, 27.4 mb