2.Electrical Service Specifications
IMPORTANT: Figures shown are for reversing models.
MD-120 Gas
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.
B.Circuit breakers are
C.Circuit breakers for
SERVICE | PHASE | WIRE | APPROX. | CIRCUIT | ||
AMP DRAW | ||||||
VOLTAGE | SERVICE | BREAKER | ||||
| 60 Hz | 50 Hz | ||||
|
|
|
| |||
208 | 3ø | 3 | 14.5 | — | 20 | |
240 | 3ø | 3 | 14.6 | — | 20 | |
230 | 3ø | 3 | — | 17.4 | 25 | |
380 | 3ø | 3 | 8.5 | — | 15 | |
380 / 400 | 3ø | 4* | — | 8.7 | 15 | |
416 | 3ø | 4* | — | 9.0 | 15 | |
440 | 3ø | 3 | 8.7 | — | 15 | |
460 / 480 | 3ø | 3 | 7.8 | — | 15 | |
575 | 3ø | 3 | 5.8 | — | 15 | |
* |
|
|
| 4/20/07 |
MD-170 Gas and Steam
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.
B.Circuit breakers are
C.Circuit breakers for
SERVICE | PHASE | WIRE | APPROX. | CIRCUIT | ||
AMP DRAW | ||||||
VOLTAGE | SERVICE | BREAKER | ||||
| 60 Hz | 50 Hz | ||||
|
|
|
| |||
208 | 3ø | 3 | 28.3 | — | 50 | |
240 | 3ø | 3 | 26.7 | — | 45 | |
230 | 3ø | 3 | — | 31.9 | 50 | |
380 | 3ø | 3 | 16.2 | — | 25 | |
380 / 400 | 3ø | 4* | — | 16.1 | 25 | |
416 | 3ø | 4* | — | 16.0 | 25 | |
440 | 3ø | 3 | 14.4 | — | 20 | |
460 / 480 | 3ø | 3 | 13.9 | — | 20 | |
575 | 3ø | 3 | 11.4 | — | 20 | |
* |
|
|
| 4/20/07 |
20 | Maytag Co. | 113395 - 6 |