American Dryer Corp MDG-120PVV Operating Steam Pressure, M. STEAM INFORMATION MD-170 Only

Models: MD-170PTVW

1 52
Download 52 pages 9.4 Kb
Page 33
Image 33
M. STEAM INFORMATION (MD-170 Only)

M. STEAM INFORMATION (MD-170 Only)

It is your responsibility to have ALL steam plumbing connections made by a qualified professional to assure that the installation is adequate and conforms to local and state regulations or codes.

IMPORTANT: Failure to comply with the requirements stipulated in this manual can result in component failure, which will VOID THE WARRANTY.

NOTE: The dryer is manufactured with a pneumatic (piston) damper system, which requires an external supply of clean, dry, regulated air (80 psi ± 10 psi [5.51 bar ± 0.68 bar]). Refer to Steam DamperAir System Connections, Section M, item 4.

1.Steam Coil pH Level

The normal pH level for copper type steam coils must be maintained between a value of 8.5 to 9.5. For steel type steam coils the pH level must be maintained between a value of 9.5 to 10.5. These limits are set to limit the acid attack of the steam coils.

IMPORTANT: Coil failure due to improper pH level will VOID THE WARRANTY.

2.Steam Requirements – High Pressure

Inlet ------ 1-1/2” supply line connection -- qty. one (1) at top manifold. Return --- 1-1/2” return line connection --- qty. one (1) at bottom manifold.

Operating Steam Pressure

Maximum

125 psig*

862 kPa

Heat Input (Normal Load)

19 Bhp

 

 

 

Consumption (Approximate)

725 lb/hr

328.85 kg/hr

Shaded areas are stated in metric equivalents

*The minimum operating pressure for optimum results is 100 psig (689.47 kPa).

3.Installation Instructions

To ensure an adequate supply of steam is provided, be sure that the steam supply lines and steam return lines are sized and laid out as stipulated in this manual. Inadequate steam supply lines and steam return lines or improper steam plumbing will result in poor performance and can cause component failure. Clean, dry steam must be provided to the dryer.

IMPORTANT: Steam coil failure due to water hammer by wet steam will VOID THE WARRANTY.

a.The pressure of the condensate in the steam supply line will cause water hammer and subsequent heat exchanger (steam coil) failure. The steam supply connection into the main supply line must be made with a minimum 10-inch (25.4 cm) riser. This will prevent any condensate from draining towards the dryer.

113395 - 6

Maytag Co.

31

Page 33
Image 33
American Dryer Corp MDG-120PVV, MD-170PTVW installation manual Operating Steam Pressure, M. STEAM INFORMATION MD-170 Only