JVC DR-MV5S Check, Cancel And Change Programs, When Programs Overlap Each Other, Rec Link, Timer

Models: DR-MV5S

1 88
Download 88 pages 42.94 Kb
Page 35
Image 35
Program’s information on the front display panel

TIMER RECORDING EN 35

 

 

Program’s information on the front display panel

 

 

You can check the details of the programs even when the power

 

 

is turned off. (it is necessary that the Power Save mode

 

 

( pg. 73) is disengaged or the unit is not in timer standby

VHS

 

mode.) However, it is not possible to cancel or change the

DVD

program’s setting.

 

 

 

A Press PROG.

“NEW PROG” or “P-1” (if 8 programs have already been set)

appears.

BPress rt until the desired program number (“P-1” to “P-8”) appears, then press ENTER.

CANCEL

C Press e.

Each time you press e, the indication changes as follows (the

 

PROG

TIMER

settings in parentheses are examples):

REC LINK

Date (“DATE 03.08SU”) ] Start time (“ON 11:00AM”) ] Stop time

ENTER

(“OFF 11:30AM”) ] Channel (“CH 1”) ] Weekly/Daily (“MO-FR

 

DAILY”) ] Program number (“P-1”) and recording mode (“SP”) ]

 

rtwe

(Back to the beginning)

DPress PROG to complete checking.

The normal display resumes.

Check, Cancel And Change Programs

1 When the DVD timer indicator lights on the front display panel

Press TIMER #, then press 1.

When “PROG” lights on the front display panel and the DVD timer indicator also lights up on the front display panel. Press 1.

When “R-LK” lights on the front display panel

Press REC LINK, then press 1.

2 Press PROG to access the Program Check screen, then press rt w e to select “VHS PRGM CHECK” or “DVD PRGM CHECK”.

To return to the previous screen after you check the program, press PROG again.

To cancel the program

Press rt to select a program to be cancelled, then press

CANCEL.

3 Press rt to select the program, then press ENTER. The program screen appears.

4 Change the settings of the desired recording options as required.

Refer to steps 5 10 in “Manual Timer Programing” ( pg. 32).

5 Press PROG to complete timer correction. The normal screen resumes.

6 For VCR Plus+, Manual or On-Disc Timer Programing (DVD deck only)

Press TIMER #.

For Automatic Satellite Program Recording

Press REC LINK for 2 seconds or more.

The DVD timer indicator also lights up on the front display panel and the VHS deck is automatically selected. When the VHS deck is in timer standby mode, the unit is automatically turned off.

NOTE:

When you check, cancel and change a On-Disc Timer Programing, be sure to insert the On-Disc Timer programed disc.

When Programs Overlap Each Other

If “PROGRAM OVERLAPPED” appears, you have another program overlapping the program you have just made.

Confirm with the arrow on “OK”, then press PROG. The Program Check screen appears and conflicting programs will be highlighted in pink.

Example: Program 3 (you have

 

VHS PRGM CHECK DVD PRGM CHECK

 

 

 

just made) and program 4

 

DATE

START

STOP

CH

DAILY/WEEKLY

REC MODE

overlap each other.

 

05/07 SAT

7:00PM - 8:00PM

44

WEEKLY

SP

 

10/07 THU

10:00PM - 10:30PM

10

 

XP

1 Confirm the overlapping

 

11/07 FRI

08:00AM - 09:00AM

26

 

LP

 

11/07 FRI

08:30AM - 09:30AM

33

 

LP

 

++++++++++++++++DVD NEW TIMER

PROGRAM ++++++++++++++++

programs. Overlapping programs

 

 

 

 

 

 

 

 

appear on the TV screen.

 

 

DISC TIMER PRGM

 

 

NOTE:

 

EXIT

OK

 

THEN PRESS [ENTER]

 

 

 

SELECT WITH [CURSORS]

If you do not mind this overlap,

 

PROG

SELECT

 

 

 

 

 

 

 

 

 

 

 

 

press PROG to finish the timer

program setting. The program whose start time is earlier will be recorded and the other one will not be recorded correctly.

2 Press rt to select the desired program to be cancelled or changed.

If program on the DVD deck and program on VHS deck overlap each other, REC LINK mark appears on the left of the date of each item. Press rt w e to select “VHS PRGM CHECK” or “DVD PRGM CHECK”, then select the program to be cancelled or changed.

To cancel the program

Press CANCEL.

“THE TIMER PROGRAMING SETTING WAS CANCELLED” appears on the TV screen for about 5 seconds, then the normal screen resumes.

To change the program setting

Press ENTER, then go to step 3.

3 Change the program setting.

Refer to steps 5 10 in “Manual Timer Programing” ( pg. 32).

4 Press PROG to check if the conflict has been settled. The Program Check screen appears.

5 Engage the unit’s timer mode.

Refer to step 6 in “Check, Cancel And Change Programs” ( pg. 35).

NOTE:

When any overlaps remain after deletion and modification of programs, the Program Check screen remains showing the conflicting programs. In such a case, repeat the procedure above until the conflict is solved.

Page 35
Image 35
JVC DR-MV5S manual Check, Cancel And Change Programs, When Programs Overlap Each Other, Rec Link, Timer Recording En, rtwe