SAFETY DEVICES | LOCATION | FUNCTION | COMPUTER DISPLAY | RESULT OF | |
M ESSAGE | TRIPPING | ||||
|
|
| |||
|
|
|
|
| |
Load Door Switch | Left side of load door | Insures dryer load doors | "DOOR OPEN" | Dryer will not run | |
are closed | |||||
|
|
|
| ||
|
|
|
|
| |
Unload Door Switch | Right side of unload door | Insures dryer unload | "DOOR OPEN" | Dryer will not run | |
door are closed | |||||
|
|
| |||
|
|
|
|
| |
Tilting Switches | Top left side of base | Insures dryer is level | "LEVEL FAULT" | Dryer will not run | |
module | |||||
|
|
|
| ||
|
|
|
|
| |
Drum Rotation Sensor | Left side of tumbler | Insures tumbler is | "DRUM FAULT" | Stops heat only | |
section | rotating | ||||
|
|
| |||
|
|
|
|
| |
Lint Chamber Air | Center of heat console | Insures proper air flow | "AIRFLOW FAULT" | Stops heat only | |
Pressure Switch | through dryer | ||||
|
|
| |||
|
|
|
|
| |
Burner Fan Air Flow |
| Insures proper |
|
| |
Switch | Center of heat console | combustion air flow into | "HEATER FAULT" | Stops heat only | |
(Gas Dryers Only) |
| the burner box |
|
| |
|
|
|
|
| |
Hi/Lo Gas Pressure | Lower left of heat | Insures proper gas supply | "GAS SUPPLY |
| |
Switch | pressure for adequate | Stops heat only | |||
console section | FAULT" | ||||
(Gas Dryers Only) | ignition |
| |||
|
|
| |||
|
|
|
|
| |
Heat Reclaimer Damper | Right side of heat | Insures that the heat | Input LED #13 of the |
| |
reclaimer is either opened | None | ||||
Switch | console | PLC is off | |||
or closed |
| ||||
|
|
|
| ||
|
|
|
|
| |
Heat Console Door | Inside heat console | Insures that access doors | "DOOR OPEN" | Dryer will not run | |
Access Door Switch | are closed | ||||
|
|
| |||
|
|
|
|
| |
Exhaust Air Temp | Inside burner section | Monitors tumbler exhaust | "EXHAUST DSFL" | Stops heat only | |
Control Sensor | duct | air temp | |||
|
| ||||
|
|
|
|
| |
Exhaust Air Hi Temp | Inside exhaust duct | Monitors tumbler exhaust | Stops heat only | ||
Control Sensor | and air temp | ||||
|
|
| |||
|
|
|
|
| |
Intake Air Temp Control | Top right of tumbler | Monitors tumbler air | "INTAKE DSFL" | Stops heat only | |
Sensor (optional) | seection | intake temp | |||
|
| ||||
|
|
|
|
| |
Intake Air Temp Control | Top right of tumbler | Monitors tumbler air | Stops heat only | ||
Sensor | section | intake temp | |||
|
| ||||
|
|
|
|
| |
Burner | Top of burner section | Monitors air temp above | Stops heat only | ||
Sensor | the burner box | ||||
|
|
| |||
|
|
|
|
| |
|
| Open sprinkler system | Orange sprinkler pilot | Opens the sprinkler | |
Sprinkler Control Safety | Top right of tumbler | water valve and | |||
water valve on | light comes on. Alarm | ||||
Sensor | section | power down the | |||
condition | sounds | ||||
|
| whole dryer | |||
|
|
|
| ||
|
|
|
|
| |
|
| Disables machine when |
|
| |
Lint Drawer Switches | Above lint drawer | drawers are open or if | Lint Drawer | Dryer will not run | |
handles | drawers have not been | ||||
|
|
| |||
|
| cleaned in last five loads |
|
| |
|
|
|
|
|