Clearing Patterns (RS485 only)

If a dome supports the clear pattern feature, then this operation will delete the programmed pattern. To clear a pattern:

1.Press the FUNCTION () key.

2.Enter the pattern number using the numeric keys.

3.Press the PATTERN () key.

4.Enter the pattern number using the numeric keys.

5.Press the FUNCTION () key.

Defining Patterns (RS232 only)

1.Press the FUNCTION () key.

2.Enter a number (1 - 3) for the pattern using the numeric keys.

3.Press the PATTERN () key

4.Maneuver the camera using the joystick to define the pattern.

5.Press the PATTERN () key

Clearing Patterns (RS232 only)

1.Press the FUNCTION () key.

2.Enter the pattern number using the numeric keys.

3.Press the PATTERN () key

4.Press the PATTERN () key to save

Initiating F2 Key Commands (RS232 only)

The Function and F1 keys on the keyboard can be used along with the numeric keyboard inputs to accomplish special functions within the MegaPower 48 system. Refer to the MegaPower 48 documentation for a listing of supported commands.

To perform an F2 special function key command:

1.Enter the number for the command using the numeric keys.

2.Hold down the FUNCTION () key.

3.Press the F1 () key.