System continued

Outlet User

You can create up to 16 independent Outlet User accounts for the

Manager

MasterSwitch VM unit. Each Outlet User is assigned a unique user

 

name, password, description, and an outlet access list, as described

 

below.

 

 

 

Current Outlet User List. The list shows the existing outlet user

 

accounts and the outlets to which they have access. To edit an existing

 

account, click on the underlined user name. To add a user, select Add

 

New User.

 

 

 

Configure the Outlet User Account Settings. Once you have

 

selected an Outlet User Account, you can configure or delete an

 

account. The following table lists and defines the configurable settings

 

for Outlet User Manager.

 

 

 

 

 

 

 

 

 

Item

Definition

 

 

 

 

 

 

 

 

 

Outlet user name for both HTTP 1.1 and MD5

 

 

 

User Name

authentication (10 characters maximum).

 

 

 

Note: A User Name in orange indicates the

 

 

 

 

 

 

 

 

user account has been disabled.

 

 

 

 

 

 

 

 

Password

Outlet user password for HTTP 1.1

 

 

 

authentication (10 characters maximum).

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet user authentication phrase for MD5

 

 

 

Authentication Phrase

authentication. The phrase must be 15–32

 

 

 

 

characters.

 

 

 

 

 

 

 

 

User Description

Identification/description of the outlet user (30

 

 

 

characters maximum).

 

 

 

 

 

 

 

 

 

 

 

 

 

Enables, disables, or deletes an outlet’s

 

 

 

 

account.

 

 

 

Account Status

Note: A disabled account prevents the Outlet

 

 

 

User of the account from logging on.

 

 

 

 

 

 

 

 

The User Name appears in orange if

 

 

 

 

the account has been disabled.

 

 

 

 

 

 

 

 

MasterSwitch VM Outlet

Selects the outlets to which users have

 

 

 

Access

access.

 

 

 

 

 

 

 

 

Delete User

Delets an outlet’s account.

 

 

 

 

 

 

Continued on next page