Technical Specifications
The table on the following pages contains the technical specifications for the Model S15 and S10 S Type Power Conditioner with Battery Backup.
FCC Compliance Information
This device complies with Part 68 and Part 15 of the Federal Communications Commission (FCC) rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
As required, the bottom of this equipment contains the Registration Number and Ringer Equivelance Number (REN) for this euipment, as well as other information. If requested, this information must be provided to the telephone company.
S10 &
S10BLK
S15 &
S15BLK
External
Battery
Pack (SBATT &
SBATTBLK)
Input:
Voltage Range for | 90V to 144V | 90V to 144V | N/A |
Operating on Utility |
|
|
|
|
|
|
|
Nominal Voltage | 120 Vac | 120 Vac | 48 Vdc |
|
|
|
|
Allowable Frequency for | 47 to 63 Hz | 47 to 63 Hz | N/A |
Operating on Utility |
|
|
|
|
|
|
|
Rated Input Current | 9 Amps | 12 Amps | N/A |
|
|
|
|
Circuit Breaker Rating | 15 Amps | 15 Amps | N/A |
|
|
|
|
Output: |
|
|
|
Number of Outlets | 12 (all outlets surge | 12 (all outlets | N/A |
| protected, | surge protected, |
|
| conditioned, | conditioned, |
|
| regulated with | regulated with |
|
| battery backup) | battery backup) |
|
|
|
|
|
Outlet Type | NEMA | NEMA | N/A |
|
|
|
|
Rated VA Capacity | 1000 VA | 1440 VA | N/A |
|
|
|
|
Rated Watt Capacity, | 700 Watts | 1000 Watts | N/A |
continuous |
|
|
|
|
|
|
|
Rated Output Current | 9 Amps | 12 Amps | N/A |
|
|
|
|