AMT Datasouth 400 manual Printers Internal Self Test Procedure and Configuration Report

Models: 400

1 76
Download 76 pages 34.49 Kb
Page 23
Image 23

Printer's Internal Self Test Procedure and Configuration Report

1.Make sure that media is installed.

2.Press and hold down the Feed Button while powering on the printer.

3.The printer will begin the Label Sensor Calibration test.

4.Continue to hold the Feed button until the Self Test begins.

5.After feeding 12 inches of blank media, the printer will begin printing out the current configuration and font list.

6.The printer will print the following information on the installed media:

Firmware version,

ROM checksum,

RS-232 settings,

Thermal transfer/Direct thermal settings,

Hardware configuration and,

Font types.

7.If the installed emulation is PPLB emulation, the printer will enter character Hex Print Mode.

8.To exit the Hex mode, press the Feed button again.

The following pages are examples of the printer's Self Test mode. The samples that you print may be different. Before requesting service, if possible, please have this page ready.