Formatting Commands

Command

Description

:xxxx

Set cut amount

An

Set print mode

 

n : ‘1’- exclusive, ‘2’ - transparent

Cxxxx

Set horizontal offset

cxx

Set cut amount

Dwh

Set pixel width and height

E

Form feed and return to system level command mode

G

Store previous data to global register

<STX>Sn

Retrieve from global register. n : global register ID

Hxx

Set heating value, xx=01 to 20

M

Toggle the mirror mode

m

Set measurement in metric

n

Set measurement in inches

Pn

Set print speed. n=’A’, ‘B’, or ‘C’ **

Qxxxx

Set copy count

Rxxxx

Set vertical offset

r<n..n>

Retrieve label data from printer buffer. <n..n> : label name

sm<n..n>

Save label data to printer buffer. m : memory module,

 

<n..n> : label name

Txx

Set end-of-line code, xx : hex value

z

Change slash zero to normal zero (0).

+xx

Make auto increment for numeric or alphanumeric,

>xx

xx : count

-xx

Make auto decrement for numeric or alphanumeric,

<xx

xx : count

^xx

Set count amount, xx : count

Notes: The formatting and editing commands should be grouped together, lead by <STX>L and ended by E command.

**: The parameter is ranged from ‘A’ to ‘C’ (1, 1.5 and 2 ips) for model FM403TT, while for models FM402DT and FM402TT it is from ‘A’ to ‘D’ (1.5, 2, 2.5 and 3 ips).