Command Set for the PPLB
All PPLB commands must end with <LF> or <CR>+<LF> codes. No spaces are allowed between parameters and leading command character.
Command | Description | Parameter | |
Ax,y,rot,font,hm,vm,nr,string | Print text. | font: 1to 5 for internal font and A to Z | |
|
|
| for soft font. |
Bx,y,rot,bar,nw,ww,v,hum,string | Print Bar Code. | nw: width of narrow bar | |
| bar: barcode | ww: width of wide bar | |
| selection | v: | bar code height |
|
| hum: B for printing readable code | |
|
|
| and N for disabling. |
bx,y,type,[…] | Print 2D Bar Code | type: M for Maxi code and P for PDF | |
|
|
| 417 |
Ccn,dn,just,step,string | Counter declaration | cn: | counter index |
|
| dn: | digit number |
|
| just: L,R,C and N for field justification | |
|
| step: step value | |
Dp1 | Heat setting | p1: | density, 0 to 15 |
EI | Print soft font |
|
|
| names |
|
|
EKstring | Delete soft font | string: soft font name or “*” to delete | |
|
|
| all soft fonts |
ESstring,…. | Download soft font |
|
|
FE | End form store |
|
|
FI | Print form names |
|
|
FKstring | Delete form | string: form name or “*” to delete all | |
|
|
| forms |
FSstring | Execute form | string: form name | |
FSstring | Save form | string: form name | |
GGx,y,string | Print graphics | string: graphic name | |
GI | Print graphic list |
|
|
GKstring | Delete graphics | string: graphic name or “*” to delete | |
|
|
| all graphics |
GMstring,size<LF>… | Store graphics | string: graphic name | |
|
| size: graphic size in bytes |
User's Guide 33