System Level Commands

Command

Description

Remarks

<STX>a

Enable page/job echo characters

 

<STX>cxxxx

Set continuous paper length and

 

 

disable edge sensor

 

<STX>Dxxxxxxx

Memory dump**

xxxxxxx : memory address in

 

 

HEX value

<STX>Exxxx

Set copy count for stored label

 

<STX>e

Enable edge sensor

 

<STX>F

Feed a page

 

<STX>fxxx

Back feed from top position

 

<STX>G

Print stored label

 

<STX>I

Download graphics

either PCX, BMP, PCX

 

 

or HEX format

<STX>J

Set pause for each label

 

<STX>j

Cancel pause

 

<STX>KQ

System configuration details

 

<STX>L

Enter label formatting state

 

<STX>Mxxxx

Set maximum label length

 

<STX>m

Set measurement in metric

 

<STX>n

Set measurement in inches

 

<STX>Oxxxx

Set start of print position

 

<STX>P

Enable data dump

 

<STX>Q

Clear memory (fonts & graphics)

 

<STX>r

Select reflective sensor

 

<STX>Sn

Set feed rate for motor

n : ‘A’, ‘B’ or ‘C’

<STX>T

Print test pattern

 

<STX>Vn

Set Cutter or Peel and Present

n : ‘1’ - enable cutter,

 

configuration

‘4’ - enable peel and

 

 

Present

<STX>v

Printer version information

 

<STX>Wn

Graphics/fonts/labels and memory

n : ‘G’, ‘F’ or ‘L’.

 

status details

RS-232 port only

<STX>x

Release file from printer memory

 

Note: **Models FM402DT and FM402TT, the memory dump command only needs a 6-digit hexadecimal.