Installation

Setting the Group Address

You must remove the translucent faceplate on the front panel before you can access the DIP switches. The GROUP ADDRESS DIP switch sets the starting address for the device numbers. For example, if the GROUP ADDRESS DIP switch is set to 128, the AXR-NWS communicates with device numbers 128 - 143.

Device numbers for ViewPoint touch panels can range from 0 - 255, but typically begin at 128; they are set within the ViewPoint’s protected setup page. Refer to the instruction manual supplied with you touch panel for detailed information. The table below lists the DIP switch values.

Group Address DIP

Switch Values

Switch

Value

11

22

34

48

516

632

764

8128

The GROUP ID DIP switch sets the identification number to synchronize communication between the wireless devices and AXR-NWS. Each AXR-NWS must have a unique GROUP ID number. All ViewPoints must match the four-position DIP switch on the AXR-NWS. FIG. 2 illustrates the relationship between Group Address and Device Address.

Group Address #128

Group ID #0

Group Address #144

Group ID #1

Device Addresses

Address

 

 

 

 

Address

 

 

 

 

#128

 

 

 

 

#143

 

 

 

 

 

 

Device Addresses

Address

 

 

 

 

 

Address

#144

 

 

 

 

 

#159

 

 

 

 

 

 

 

FIG. 2 Relationship between Group Address and Device Address

To use 32 wireless devices, use two AXR-NWS Servers set to two different Group IDs. The first Server is set to GROUP ID # that supplies the addresses 128 - 143. The second Server is set to the GROUP ID# that supplies the addresses 144 - 159.

 

4

AXR-NWS NetWave Server

 

 

 

Page 8
Image 8
AMX AXR-NWS instruction manual Setting the Group Address, Group Address DIP Switch Values