Serial Control Strings

Command Messages (Cont.)

MGFVr,s

Get the favorite, where:

Favorite Status:

 

1) ‘r’ is the desired room, (1-64)

"MFAVr,s,f"

 

2) ‘s’ is the desired source, valid values are

where:

 

1-8

1) 'r' is the room, values from [1..64]

 

 

2) 's' is the source, values are 1-8

 

 

3) 'f' is the direct tuning string; it can be from

 

 

0 to 7 characters long and is translated

 

 

as specified in the 'Send Source Direct

 

 

Data' command: Zero length data is

 

 

returned if the favorite is not set

 

 

- or -

 

 

ERR

 

 

 

MSLOr

Lock out the keypad in a room, where:

Keypad Lock Out Status:

 

‘r’ is the room to lock out, (1-64)

"MLOTb8,b7,b6,b5,b4,b3,b2,b1"

 

 

where:

 

 

'b8'…'b1' is a binary room selection bitmap

 

 

where all rooms blocked out have a binary 1 in

 

 

the room position. The most significant bit in

 

 

'b8' is for room 64 and the least

 

 

significant bit in 'b1' is for room 1

 

 

- or -

 

 

ERR

 

 

 

MCLOr

Clear the keypad lock out in a room, where:

Keypad Lock Out Status:

 

‘r’ is the room to clear the lock out in, (1-64)

"MLOTb8,b7,b6,b5,b4,b3,b2,b1"

 

 

where:

 

 

'b8'…'b1' is a binary room selection bitmap

 

 

where all rooms blocked out have a binary 1 in

 

 

the room position. The most significant bit in

 

 

'b8' is for room 64 and the least

 

 

significant bit in 'b1' is for room 1

 

 

- or -

 

 

ERR

 

 

 

MGLO

Get the keypad lock out status for the sys-

Keypad Lock Out Status:

 

tem.

"MLOTb8,b7,b6,b5,b4,b3,b2,b1"

 

 

where:

 

 

'b8'…'b1' is a binary room selection bitmap

 

 

where all rooms blocked out have a binary 1 in

 

 

the room position. The most significant bit in

 

 

'b8' is for room 64 and the least

 

 

significant bit in 'b1' is for room 1

 

 

- or -

 

 

ERR

 

 

 

MSPSs,n,p

Set the preset, where:

Preset Status:

 

1) ‘s’ is the desired source, (1-8)

"MPRSs,n,p"

 

2) ‘n’ is the desired preset, (1-10)

where:

 

3) ‘p’ is the direct tuning string; it can be from

1) 's' is the source, valid values are 1-8

 

0 to 7 characters long and is translated as

2) 'n' is the preset, valid values are 1-10

 

specified in the ‘Send Source Direct Data’

3) 'p' is the direct tuning string; it can be

 

command: Zero length data will clear the

from 0 to 7 characters long and is

 

preset.

 

translated as specified in the 'Send

 

 

 

 

Source Direct Data' command: Zero

 

 

length data is returned if no preset is set.

 

 

- or -

 

 

ERR

 

 

 

74

Mi Series and Tango Audio Controllers

Page 86
Image 86
AMX DAS-T0804-SIG, DAS-T0808-SIG manual MGFVr,s, MSLOr, MCLOr, Mglo, MSPSs,n,p

DAS-T0808-SIG, DAS-T0804-SIG specifications

The AMX DAS-T0804-SIG and DAS-T0808-SIG are the forefront of advanced data distribution systems, designed to cater to the dynamic needs of commercial audio-visual installations. These models provide exceptional performance in managing and distributing various signals efficiently, ensuring seamless integration with a wide array of multimedia components.

One of the standout features of the DAS-T0804-SIG is its ability to support up to four output signals, while the DAS-T0808-SIG extends this capability to eight outputs. This scalability makes both units ideal for projects requiring flexible signal routing, whether for corporate environments, educational institutions, or entertainment venues.

Both models leverage cutting-edge digital signal processing (DSP) technologies to enhance audio quality and ensure fidelity during signal transmission. The units are equipped with advanced signal management features, including automatic gain control and equalization, which help maintain consistent audio levels and optimize playback across different environments. This ensures that users experience high-quality sound without the hassle of manual adjustments.

Connectivity options are plentiful, with support for both HDMI and analog inputs. The HDMI ports allow for seamless integration with high-definition video sources, while the analog inputs cater to older equipment, making the DAS-T0804-SIG and DAS-T0808-SIG versatile choices for mixed-system setups. The ability to handle diverse input types helps manage the challenges of modern AV environments, where devices can vary widely.

Another notable characteristic is the intuitive user interface that facilitates easy configuration and operation. The models come equipped with LED indicators for monitoring signal status, which provide real-time feedback and help troubleshoot issues swiftly. This user-centric design is particularly beneficial for installation professionals who require efficient workflows.

The DAS-T0804-SIG and DAS-T0808-SIG are also built with robust security features to protect against unauthorized access and ensure integrity in signal transmission. This is increasingly crucial in settings where sensitive information may be communicated.

In summary, the AMX DAS-T0804-SIG and DAS-T0808-SIG systems are powerful, flexible, and secure solutions for modern AV installations, characterized by their advanced signal processing, versatile connectivity, and intuitive design. Their ability to accommodate a variety of applications makes them an essential tool for any professional seeking to optimize audio-visual performance.