Serial Control Strings

Status Messages

Status Messages

ERR

Error

 

 

ACK

Acknowledge Status

 

 

PON

Power On Status

 

Note: Not used

 

 

POFF

Power Off Status

 

Note: Not used

 

 

MVERx

Firmware Version Status, where ‘x’ is the current firmware version (4 digits)

 

 

MCFr,s,z,c

Configuration Status, where:

 

1)

'r' is the number of rooms connected, (2-64)

 

2)

's' is the number of sources connected, (4,6, or 8)

 

3)

'z' is the number of groups available, (r/2)

 

4)

'c' is the clock available status, (0-1) where:

 

 

0: no clock installed

 

 

1: clock module is present

 

 

FNICxx

Num IIC Devices Status, where ‘xx’ denotes the number of IIC devices available in the

 

MRC

 

 

FSICx,a,v,p,d

IIC Device Status, where:

 

1) ‘x’ is the IIC device index, valid values range from 1 to the number of IIC devices as

 

 

denoted in the ‘Num IIC Devices Status’

 

2)

‘a’ is the device ID (3 digits)

 

3)

’v’ is the version (4 digits)

 

4)

‘p’ is the product ID (4 digits)

 

5)

‘d’ is a descriptive string for the device, the string is of variable length

 

 

AMXB

AMX Beacon Response, where

<-UUID=v>

1) 'v' = 'MATRIX-CTRL'

<-SDKClass=w>

2)

'w' is 'DCTRL'

<-Make=x>

3)

'x' is 'AMX'

<-Model=y>

4) 'y' is 'MI-4', 'MI-6', OR 'MI-8' depending on controller hardware

<-Revision=z>

 

5)

'z' denotes the current firmware version

 

(Note: v7.02 or higher only)

 

 

BAUD:x

Baud Rate Status, where,

 

‘x’ is the current Baud Rate (4 digits)

 

(Note: v7 or higher only)

 

 

MVLr,v

Volume Status, where:

 

1)

'r' denotes the room, (1-64)

 

2)

'v' denotes the volume setting, (0-70, 101)

 

 

101: Mute

 

 

0..70: 0..-70 dB

 

 

MBSr,b

Bass Status, where:

 

1)

'r' denotes the room, (1-64)

 

2)

'b' denotes the bass level, (0-20)

 

 

0: level

 

 

1..10: -10..-1 dB

 

 

11..20: 1..10 dB

 

 

MTRr,t

Treble Status, where:

 

1)

'r' denotes the room, (1-64)

 

2)

't' denotes the bass level, (0-20)

 

 

0: level

 

 

1..10: -10..-1 dB

 

 

11..20: 1..10 dB

 

 

 

80

Mi Series and Tango Audio Controllers

Page 92
Image 92
AMX DAS-T0804-SIG, DAS-T0808-SIG manual Status Messages

DAS-T0808-SIG, DAS-T0804-SIG specifications

The AMX DAS-T0804-SIG and DAS-T0808-SIG are the forefront of advanced data distribution systems, designed to cater to the dynamic needs of commercial audio-visual installations. These models provide exceptional performance in managing and distributing various signals efficiently, ensuring seamless integration with a wide array of multimedia components.

One of the standout features of the DAS-T0804-SIG is its ability to support up to four output signals, while the DAS-T0808-SIG extends this capability to eight outputs. This scalability makes both units ideal for projects requiring flexible signal routing, whether for corporate environments, educational institutions, or entertainment venues.

Both models leverage cutting-edge digital signal processing (DSP) technologies to enhance audio quality and ensure fidelity during signal transmission. The units are equipped with advanced signal management features, including automatic gain control and equalization, which help maintain consistent audio levels and optimize playback across different environments. This ensures that users experience high-quality sound without the hassle of manual adjustments.

Connectivity options are plentiful, with support for both HDMI and analog inputs. The HDMI ports allow for seamless integration with high-definition video sources, while the analog inputs cater to older equipment, making the DAS-T0804-SIG and DAS-T0808-SIG versatile choices for mixed-system setups. The ability to handle diverse input types helps manage the challenges of modern AV environments, where devices can vary widely.

Another notable characteristic is the intuitive user interface that facilitates easy configuration and operation. The models come equipped with LED indicators for monitoring signal status, which provide real-time feedback and help troubleshoot issues swiftly. This user-centric design is particularly beneficial for installation professionals who require efficient workflows.

The DAS-T0804-SIG and DAS-T0808-SIG are also built with robust security features to protect against unauthorized access and ensure integrity in signal transmission. This is increasingly crucial in settings where sensitive information may be communicated.

In summary, the AMX DAS-T0804-SIG and DAS-T0808-SIG systems are powerful, flexible, and secure solutions for modern AV installations, characterized by their advanced signal processing, versatile connectivity, and intuitive design. Their ability to accommodate a variety of applications makes them an essential tool for any professional seeking to optimize audio-visual performance.