Anetsberger Brothers MX-7A, MX-7E FRYER TROUBLESHOOTING GUIDE Continued, Problem, Cause, Remedy

Models: MX-14-2AA MX-7A MX-14-2E MX-14AA MX-14E MX-7E

1 28
Download 28 pages 63.12 Kb
Page 22
Image 22
recalibrated.

FRYER TROUBLESHOOTING GUIDE (Continued)

PROBLEM

CAUSE

REMEDY

 

 

 

Liquid shortening does

1. Low gas supply pressure [less than 6W.C.

1. Measure the gas supply pres-

not reach the desired

for natural gas; (11W.C. for propane)

sure.

temperature for frying.

when all other gas-powered equipment is

Contact your local gas supplier

 

operating], causing reduced heat from main

to obtain adequate gas supply

 

burners.

pressure.

 

2. Low gas manifold pressure [less than 3½

2. Measure the gas pressure at

 

W.C. for natural gas; (10W.C. for pro-

the fryer’s manifold pressure

 

pane)].

tap. Adjust the manifold pres-

 

 

sure (see Figure 6), as neces-

 

 

sary: [a] Unscrew (and re-

 

 

tain) the threaded Main Burner

 

 

Regulator Adjustment Cover.

 

 

Use a flat-blade screwdriver to

 

 

turn the regulator adjustment

 

 

screw (clockwise to increase;

 

 

counterclockwise to decrease)

 

 

to reset the pressure adjust-

 

 

ment. Reinstall, and tighten,

 

 

the Regulator Adjustment

 

 

Cover, when finished.

 

3. Loose knob on thermostat; or thermostat

3. Stir the shortening to mix the

 

requires calibration (temperature setting dif-

hot shortening with some from

 

fers by about 10°F from measured shorten-

the lower ‘cool zone’ and allow

 

ing temperature).

it to sit for 5 minutes. Turn the

 

 

thermostat knob until it ‘clicks’

 

 

on (causing the main burners to

 

 

flame); note the setting where

 

 

this occurs. Turn the thermo-

 

 

stat until it ‘clicks’ off (causing

 

 

the main burners to go out);

 

 

note the setting where this

 

 

occurs. Repeat this tempera-

 

 

ture ‘click points’ step at least

 

 

three times to ensure that

 

 

the shortening temperature has

 

 

stabilized.

 

 

Measure the temperature of

 

 

the shortening by inserting an

 

 

accurate thermometer about

 

 

4 inches into the shortening to

 

 

measure its temperature. If the

 

 

temperature variation between

 

 

the measured temperature and

 

 

the thermostat setting is 10°F

 

 

or less, the thermostat can be

 

 

recalibrated.

22

Page 22
Image 22