Chapter 1 General Information
Table 1-1. Performance Specifications (1 of 2)
Specifications are valid when the unit is calibrated at ambient temperature after a 5 minute warmup.
Description
Site Master:
S251B
Frequency Accuracy (RF Source Mode):
Frequency Resolution:
SWR:
Range
Resolution
Return Loss:
Range
Resolution
Insertion Loss/Gain
Range:
Resolution
RF Source
Frequency
Power Output (nominal)
Wattmeter Power Monitor:
Range
Offset Range
Resolution
Value
Frequency Range:
625 to 2500 MHz
75 parts per million @ 25°C*
10 kHz
1.00to 65.00
0.00to 54.00 dB
0.01dB
0 to (Resolution x dp) (1.5 108)(Vf )
F
Where Vf is the relative propagation velocity of the cable .
dp is the number of data points (128, 256, 512).
F is F2 - F1 (in Hz.)
625 to 2500 MHz @ 10 kHz step selectable, – 30 dBm or + 6 dBm
10.0pW to 100.0 kW 0 to +60.0 dB
0.1dB or
0.1xW
Test Port, Type N | 50 Ohms |
***Immunity to Interfering signals |
|
up to the level of: RF Out | +10 dBm, reflection |
RF In | + 30 dBc transmission |
Maximum Input (Damage Level): |
|
Test Port, Type N | +22 dBm |
RF Detector | +20 dBm |
Measurement Accuracy:
Measurement accuracy depends on calibration components. Precision calibration load provides a corrected directivity of 42 dB.
Cable Insertion Loss: |
|
Range | 0.00 to 54.00 dB |
Resolution | 0.01 dB |
1 - 4