OPERATING THE IMY
After completing all
QUICK PROGRAMMING
To limit access to the
The other operations in the “quick programming” mode require special key sequences as shown:
To reset latched alarm, scroll through steps in “quick programming” mode using the “P” button until “LAtCH1” or “LAtCH2” appears in the display. If they do not appear, they are not latched.
To reset: While “LAtCH1” or “LAtCH2” is being displayed, press and hold “DOWN” and press “P”. Pressing “P” alone causes a step to the next item with no action on the alarm.
To reset peak and valley buffers, scroll through steps in “quick programming” mode using the “P” button until “PEA” or “VAL” appears in the display.
To reset: While “PEA” or “VAL” is being displayed, press and hold “DOWN” and press “P”. Pressing “P” alone causes a step to the next item with no action taken on the buffer.
The front panel buttons are not only used to input data during the programming and “quick programming” mode, but control a number of other functions (if enabled in Pro “3”) as well. In the normal meter mode, these functions are available:
To switch to display of input: Press “DOWN” button.
To switch to display of totalizer: Press “UP” button.
To reset totalizer to zero: Press and hold “UP” and press “P”.
To enter programming or “quick programming”: Press “P”.
After each operation, a message will appear briefly to acknowledge the action.