20. CERTIFICATIONS AND COMPLIANCES:

SAFETY

IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment for measurement, control and laboratory use, Part 1.

IP65 Enclosure rating (Face only), IEC 529 Type 4 Enclosure rating (Face only), UL50

ELECTROMAGNETIC COMPATIBILITY

Immunity to EN 50082-2

EN 61000-4-2 Level 2; 4

Kv contact 1

Electrostatic discharge

Electromagnetic RF fields

EN 61000-4-3

Level 3; 8

Kv air

Level 3; 10 V/m 2

Fast transients (burst)

EN 61000-4-4

80 MHz - 1 GHz

Level 4; 2

Kv I/O

RF conducted interference

EN 61000-4-6

Level 3; 2

Kv power

Level 3; 10 V/rms

 

 

150 KHz - 80 MHz

Emissions to EN 50081-2

EN 55011

Enclosure class A

RF interference

Notes:

 

Power mains class A

 

 

 

1. Metal bezel of unit connected with ground lead from rear bezel screw to metal mounting panel.

2. Self-recoverable loss of performance during EMI disturbance at 10 V/m: Process input and/or analog output signal may vary during EMI disturbance. For operation without loss of performance:

Unit is mounted in a metal enclosure (Buckeye SM7013-0 or equivalent) I/O and power cables are routed in metal conduit connected to earth ground.

Refer to the EMC Installation Guidelines for additional information.

21. CONSTRUCTION: Die-cast metal front bezel that meets NEMA 4/IP65 requirements for wash-down and/or dusty environments when properly installed. Pollution Degree 2. Case body is black, high impact plastic (panel gasket and mounting clips included).