Start Up & Setting Operating Controls

HEATER CONTROLS...continued

Start Up & Setting Operating Controls

Owner-Level Programming Instructions...continued:

4. Selecting Pool/Spa Thermostat Settings:

A.Depress the [POOL/SPA] key to toggle between the pool and the spa temperature set points.

B.The pool/spa LED indicator lights, located to the left of the temperature display, will confirm the selected set point.

5.Changing The Pool Temperature Set Point:

A.Using the [POOL/SPA] key, select the POOL temperature set point. The pool set point indicator light will confirm the selection.

B.The pool temperature set point is adjustable from a minimum of 45oF to a maximum of

104oF. Depressing the [UP ARROW] key will raise the set point 1-degree for every push of the button. Depressing the [DOWN ARROW] key will lower the set point 1-degree for every push of the button.

6.Changing The Spa Temperature Set Point:

A.Using the [POOL/SPA] key, select the SPA temperature set point. The spa set point indicator light will confirm the selection.

B.The spa temperature set point is adjustable from a minimum of 45oF to a maximum of

104oF. Depressing the [UP ARROW] key will raise the set point 1-degree for every push of the button. Depressing the [DOWN ARROW] key will lower the set point 1-degree for every push of the button.

7.Selecting Between oF and oC:

A.Simultaneously depress and hold both the [UP ARROW] and [DOWN ARROW] keys until [CF1] (Celsius / Fahrenheit) code appears.

B.With the [CF1] code displayed, pressing the [UP ARROW] or [DOWN ARROW] keys will change the selection code to either “0” or “1”. Select “1” for Fahrenheit temperature display, or “0” for Celsius temperature display. Once the desired temperature display mode has been selected, not pressing any buttons for 15-seconds will allow the controller to save the selection and return to the normal operating mode. Pressing the {POOL/SPA] key will also save the selection and step to the next menu parameter: [ULC] (User Lock Code).

8.User Lock Code Option [ULC]: This Option Explained:

Heat pumps are shipped from the factory with the [ULC] option disabled. Enabling the [ULC] function permits the heat pump owner to restrict access to the unit’s controls. With the [ULC] function enabled, unless the correct ULC code number is entered, changes to Level-1 programming are not possible. (I.e.: Altering temperature set points, Pool/Spa selection, C/F display changes, etc., will not be possible). The [ULC] option can be thought of as an electronic lockable cover for the controls.

(Continued on Next Page)