Controls Configuration & Adjustments

Controls Configuration & Adjustments

Level-2 (Dealer-Service) Microprocessor Programming

(Includes Configuration for External Controllers)

Level-2 programming involves configuring the controller for specific site characteristics. To explain, this programming is where the controller is set to operate with, or without, an external controller; where sensor calibrations are performed; and where changes to other factory default parameters are made.

Before transferring use of the heater to the owner, the installer must insure the controller programming is compatible with any site-installed external controllers, and that the heater starts and operates per the manufacturer’s specifications.

Generally speaking, the installer’s main focus within Level-2 programming will be in configuring for external controller compatibility. And, unless instructed to do otherwise by the AquaCal Technical Support Group, the installer should not adjust sensor calibration or dead-band values.

CAUTION !

Failure to heed the following may result in equipment damage

and voiding of manufacturer’s warranty.

 

 

Heat pumps contain no owner-serviceable components. Owner-initiated adjustments, beyond the controller “LOC” code, must not be attempted. If adjustments are deemed necessary, the owner should contact installing dealer or AquaCal Customer Support at (800) 786-7751.

1.Entering Service Menu:

A.To enter the service menu, Simultaneously depress and hold both the [UP ARROW] and [DOWN ARROW] keys until [CF1] (Celsius / Fahrenheit) code appears. (Note: if “000” displays, the User Lock Code is enabled, and the ULC pass code must be entered before proceeding. See Owner-Level Operating Instructions, page-14: “User Lock Code Option [ULC].” If the owner’s ULC pass code is unknown, the factory default code “17” may be used to access controller programming.) Depress the [POOL/SPA] key four times to display [LOC], which is the entrance point for the Service Menu.

B.The [LOC] code allows service personnel the ability to enter and access code to enter the service menu. This includes the above-mentioned codes that have adjustable parameters in the software that may require calibration or adjustment. This section of the menu is intended for authorized factory service personnel only.

C.Using the [UP] and [DOWN] arrow keys scroll the displayed number to “50.”

D.Once the correct service code is displayed pressing the [POOL/SPA] key, one again, will allow access to the service menu.

E.The first service parameter displayed will be [dEL] (4 -minute time delay on make).

NOTE: Depressing the [POOL/SPA] key will save the displayed value in any menu parameter and advance to the next service menu parameter.