Controls Configuration & Adjustments...
Water Flow (Pressure) Switch Adjustment
Occasionally, plumbing system design features will create a situation whereas the heater will abnormally cycle on the water flow circuit. This situation will be evident if the circulator pump is operating, the filter is clean, and all water valves are set to flow water through the heater– but the error code: “FLO” remains displayed (or displays intermittently). In these rare instances where the factory water pressure switch (WPS) setting will not satisfy site conditions, a WPS adjustment, to enable normal heater operation, is possible.
WARNING ! | Failure to heed the following may result in permanent injury |
or death. | |
|
|
WPS adjustment procedure to be performed by experienced service personnel only; procedure is NOT a
Locate Water Pressure Switch and Identify Type:
1. Before proceeding with switch adjustment, be absolutely certain the heater is receiving correct water flow. Leave circulation pump operating during water pressure switch (WPS) adjustment process.
2.Remove heater front cover and locate the water pressure switch. The switch will be found attached outside of the electrical enclosure, at lower edge; exact location will vary by heater model (see photo
3.AquaCal heat pumps may come equipped with either of two (2) water pressure switches: “Len Gordon” or “TecMark” brand (see photos
To Adjust a “Len Gordon” Switch:
1.Locate the black, rectangular plastic tab, located on the
2.With water pump operating, and electrical power supplied to the heater, slowly rotate the top of the adjustment wheel TOWARDS you until the FLO code (just) disappears. WARNING: watch for rotating fan blade; depending upon the state of the control circuit time delay, the heater may start simultaneous with the WPS adjustment.
3.Once the adjustment has been completed, slide the wheel locking tab fully back to the right- hand, locked position.
To Adjust a “TecMark” Switch:
1.(Reference photo
2.With water pump operating, and electrical power supplied to the heater, slowly rotate the top of the adjustment wheel AWAY from you until the until the FLO code (just) disappears. WARNING: watch for rotating fan blade; depending upon the state of the control circuit time delay, the heater may start simultaneous with the WPS adjustment.
56