5.Defrost Sensor Calibration...continued: Controls Configuration & Adjustments...

Level-2 Microprocessor Programming...continued:

5.Defrost Sensor Calibration...continued:

H.Once the correct temperature value has been selected not pressing depressing any buttons for 15 seconds will allow the controller to save the selection and return to the normal operating mode. Pressing the [POOL/SPA] key will also save the selection and step to the next menu parameter [dBS], (Dead Band for Spa).

6.Spa Dead Band Differential [dBS]:

The dead band differential determines the number of degrees that the water temperature must fall below the set point before the thermostat closes (Heat Mode). In the cooling mode the dead band differential determines the number of degrees that the water temperature must rise above the set point before the thermostat closes again. When in the auto-changeover mode the dead band differential operates in the same manner as described above for heating mode and cooling modes. However, in all modes the thermostat will open when the set point is reached independently of the direction the water temperature is changing. The factory spa dead band differential is set to 1oF. It is highly recommended that the factory default of 1oF remain, however, if form some reason the dead band requires adjustment, follow the steps outlined below:

A.Follow the steps 1a. through 1d. above to enter the service menu. Once [dEL] is displayed, press the [POOL/SPA] key until the display shows [dBS] (Spa Dead Band Differential).

B.With the service menu parameter [dBS] displayed, pressing either the [UP] or [DOWN] arrow keys once will display the current setting. Using the [UP] or [DOWN] arrows keys will increase or decrease the value respectively. The differential is adjustable in 1o increments from 1 to 5-degrees.

C.Once the desired dead band value has been selected not pressing depressing any buttons for 15 seconds will allow the controller to save the selection and return to the normal operating mode. Pressing the {POOL/SPA] key will also save the selection and step to the next menu parameter [dBP], (Dead Band Pool).

7.Pool Dead Band Differential [dBP]:

The dead band differential determines the number of degrees that the water temperature must fall below the set point before the thermostat closes (Heat Mode). In the cooling mode the dead band differential determines the number of degrees that the water temperature must rise above the set point before the thermostat closes again. When in the auto-changeover mode the dead band differential operates in the same manner as described above for heating mode and cooling modes. However, in all modes the thermostat will open when the set point is reached independently of the direction the water temperature is changing. The factory pool dead band differential is set to 1oF. It is highly recommended that the factory default of 1oF remain, however, if form some reason the dead band requires adjustment, follow the steps outlined below:

A.Follow the steps 1a. through 1d. above to enter the service menu. Once [dEL] is displayed, press the [POOL/SPA] key until the display shows [dBP] (Pool Dead Band Differential).

B.With the service menu parameter [dBP] displayed, pressing either the [UP] or [DOWN] arrow keys once will display the current setting. Using the [UP] or [DOWN] arrows keys will increase or decrease the value respectively. The differential is adjustable in 1o increments from 1 to 5 degrees.

(Continued on Next Page)

49

Page 49
Image 49
Aquacal 100 owner manual Controls Configuration & Adjustments, Level-2Microprocessor Programming...continued