maintenance guide

Manual Air vent

Tools

1

Time

5 min

Remove the clip and lift the manual air vent from the exchanger

Main Heat Exchanger

Tools

Time

20 min

1

Drain boiler (see 3.3). Remove the four clips

Isolate the gas supply. Remove the four

Remove the four screws to free the heat ex-

and disconnect the two pipes between the

screws and disconnect the gas pipe from

changer

exchanger and pump and between the ex-

the gas valve

 

changer and left hand hydraulic block

 

 

2

Pull the heat exchanger towards you

Remove the clip and lift the manual air vent

Twist the thermal fuse to remove