maintenance guide

Annual Maintenance

Plate heat exchanger

Maintenance Interval: As necessary

How: To measure specifi- cation of DHW perfor- mance.

By-pass & Safety valve

Maintenance Interval: Annually

How: Visual inspection / Clean as necessary

Central heating filter

Maintenance Interval: Annually

How: Visual inspection / Clean as necessary

Flow switch operation

Maintenance Interval: Annually

How: Visual inspection / Clean as necessary

/ Check flow rate

Expansion vessel

Maintenance Interval: Annually

How: Check air pressu- re is at 1 bar (System drained)

Ignition & detection electrodes

Maintenance Interval: Annually

How: Visual inspection / Clean as necessary / Di- stance from the burner / Ionisation current more than 1 μA

Burner

Maintenance Interval: Annually

How: Visual inspection / Clean as necessary

Fan

Maintenance Interval: Annually

How : Visual inspection / Clean as necessary

Primary Heat exchanger

Maintenance Interval: Annually

How : Visual inspection / Clean as necessary

Condensate trap

Maintenance Interval: Annually

or after cleaning primary heat exchanger

How: Visual inspection / Clean as necessary / Add water before replacing

Pump

Maintenance Interval: At the first ignition and annually

How: Check that the AAV is open /

Visual inspection / Clean as necessary