maintenance guide

By-Pass Assembly

Tools

Time

5 min

1

Drain boiler (see 3.3). Remove the second clip and pull the assembly toward you

Push on the by-pass to disengage it

Temperature Sensor

Tools

Time

5 min

NTC1 NTC2

1

 

NTC1 : Black wires

Unplug the electrical connectors

Remove the clip and the temperature sensor

 

NTC2 : Grey wires

 

 

 

 

 

 

 

 

 

TEMPERATURE (°C)

 

 

RESISTANCE (kOmh)

 

 

 

 

 

 

0

 

 

27

 

10

 

 

17

 

20

 

 

12

 

25

 

 

10

 

30

 

 

8

 

40

 

 

5

 

50

 

 

4

 

60

 

 

3

 

70

 

 

2

 

80

 

 

1,5