maintenance guide

Burner

Tools

Time

15 min

1

Remove the silencer

Isolate the gas supply. Remove the four Pull the assembly towards you

 

screws and disconnect the gas pipe from

 

the gas valve

 

 

 

Note: Any work carried out on the

 

combustion assembly requires

 

a combustion analysis check on

 

completion of work

2

Remove the three screws to free the burner door

Pull the burner toward you

2

1

 

 

3

 

 

 

 

 

1.Stainless Steel Burner

Power

Length

Venturi

 

 

 

24 KW

104.6 mm

Ø 42 mm

 

 

 

 

 

2. Ignition electrode

30 KW

135.8 mm

/

3.Detection electrode

38 KW

167 mm

/

48

Page 48
Image 48
Ariston E-COMBI 24 30 38 manual Burner, Power Length Venturi