Connecting the Flue

Flue System

The provision for satisfactory flue termination must be made as described in BS 5440-1.

The appliance must be installed so that the flue terminal is exposed to outdoor air.

The terminal must not discharge into another room or space such as an outhouse or lean-to.

It is important that the position of the terminal allows a free passage of air across it at all times.

The terminal should be located with due regard for the damage or discolouration that might occur on buildings in the vicinity, it must also be located in a place not likely to cause nuisance.

In cold or humid weather water vapour may condense on leaving the flue terminal.

The effect of such “steaming” must be considered.

If the terminal is less than 2 metres above a balcony, above ground or above a flat roof to which people have access, then a suitable stainless steel terminal guard must be fitted.

The minimum acceptable spacing from the terminal to obstructions and ventilation openings are specified in Fig. 1.

Where 2 or more vertical fanned draught chimney configurations teminate in close proximity at the same height they shall be separated by at least 300mm. Where any 1 vertical outlet is more than 300mm above the other, then they shall be separated by at least 1500mm.

Fig. 1

 

- A Directly below an opening, window, etc

300 mm

- B Horizontally to an opening, window, etc

300 mm

- C Below gutters, soils pipes or drain pipes

75 mm

- D Below eaves

200 mm

- E From vertical drain pipe or soil pipe

75 mm

- F From internal or external corner

300 mm

- G Above ground, roof or balcony level

300 mm

- H From a surface facing the terminal

600 mm

- I From a terminal facing a terminal

1200 mm

- J Vertically from a terminal on the same wall

1500 mm

- K Horizontally from an terminal on the same wall

300 mm

- L Fixed by vertical flue terminal

 

See table

180

See table on page 22

4

118mm

Fig. 2

Warning

The exhaust gas ducts must not be in contact with or close to inflammable material and must not pass through building structures or walls made of inflammable material.

When replacing an old appliance, the flue system must be changed.

Important

Ensure that the flue is not blocked.

Ensure that the flue is supported and assembled in accordance with these instructions.